z-logo
Premium
Signal, noise, and detective quantum efficiency of a‐Si:H flat‐panel imagers
Author(s) -
Siewerdsen Jeffrey H.
Publication year - 1998
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.598427
Subject(s) - detective quantum efficiency , optics , medical imaging , noise (video) , image sensor , signal to noise ratio (imaging) , flat panel detector , computed radiography , flat panel , image resolution , signal (programming language) , computer science , image quality , physics , detector , artificial intelligence , image (mathematics) , programming language
Flat‐panel imagers based upon the technology of thin‐film amorphous silicon transistors and photodiodes are under investigation for a wide variety of medical imaging applications. This thesis presents quantitative empirical and theoretical investigations of the imaging performance of such imaging systems. Performance was evaluated in terms of imager signal size, spatial resolution, noise characteristics, and signal‐to‐noise ratio for a wide variety of imaging system configurations and exposure conditions relevant to medical imaging. A theoretical model based upon cascaded systems analysis allowed prediction of imager signal, noise, and detective quantum efficiency (DQE), and theoretical results were found to agree well with empirical measurements. The empirical and theoretical analyses yielded quantification of the performance of existing imager designs, allowed investigation of the potential performance of future flat‐panel imaging systems, and provided a methodology for identifying optimal imager configurations for various applications and imaging tasks. There is every indication that flat‐panel imagers could provide performance superior to that of existing clinical imaging technologies. For example, in general x‐ray radiography, mammography, and radiotherapy portal imaging, such systems could provide DQE exceeding 60%, 80%, and 1.5%, respectively, approximately twice that of film‐based systems. However, for applications involving very low exposures per image, e.g., real‐time fluoroscopy, flat‐panel imagers may suffer from reduced signal‐to‐noise ratio. The analyses developed in this thesis provide a general description of imager signal and noise as well as a means of identifying strategies for improved imager performance.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here