Premium
Use of an octree‐like geometry for 3‐D dose calculations
Author(s) -
McShan D. L.,
Fraass B. A.
Publication year - 1993
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.597151
Subject(s) - octree , geometry , physics , computer science , mathematics , artificial intelligence
A representation used for 3‐D graphical objects, the “octree,” has been applied to the geometrical calculations needed to perform photon beam dose calculations for radiotherapy treatment planning. This representation allows the algorithm to attempt to minimize the number of distinct geometrical calculations that are needed to perform dose calculations to a particular resolution. In this way, the calculational time can be minimized, since the geometrical part of the dose calculations is often the most time‐intensive part of the calculation process. The octree‐like system used here has sped up the photon dose calculations described here by up to a factor of 10.