z-logo
Premium
Investigating deformable image registration and scatter correction for CBCT‐based dose calculation in adaptive IMPT
Author(s) -
Kurz Christopher,
Kamp Florian,
Park YangKyun,
Zöllner Christoph,
Rit Simon,
Hansen David,
Podesta Mark,
Sharp Gregory C.,
Li Minglun,
Reiner Michael,
Hofmaier Jan,
Neppl Sebastian,
Thieke Christian,
Nijhuis Reinoud,
Ganswindt Ute,
Belka Claus,
Winey Brian A.,
Parodi Katia,
Landry Guillaume
Publication year - 2016
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.4962933
Subject(s) - proton therapy , image registration , nuclear medicine , medicine , cone beam computed tomography , image guided radiation therapy , prostate cancer , radiation treatment planning , radiation therapy , computed tomography , computer science , artificial intelligence , radiology , cancer , image (mathematics)
Purpose This work aims at investigating intensity corrected cone‐beam x‐ray computed tomography (CBCT) images for accurate dose calculation in adaptive intensity modulated proton therapy (IMPT) for prostate and head and neck (H&N) cancer. A deformable image registration (DIR)‐based method and a scatter correction approach using the image data obtained from DIR as prior are characterized and compared on the basis of the same clinical patient cohort for the first time. Methods Planning CT (pCT) and daily CBCT data (reconstructed images and measured projections) of four H&N and four prostate cancer patients have been considered in this study. A previously validated Morphons algorithm was used for DIR of the planning CT to the current CBCT image, yielding a so‐called virtual CT (vCT). For the first time, this approach was translated from H&N to prostate cancer cases in the scope of proton therapy. The warped pCT images were also used as prior for scatter correction of the CBCT projections for both tumor sites. Single field uniform dose and IMPT (only for H&N cases) treatment plans have been generated with a research version of a commercial planning system. Dose calculations on vCT and scatter corrected CBCT (CBCT cor ) were compared by means of the proton range and a gamma‐index analysis. For the H&N cases, an additional diagnostic replanning CT (rpCT) acquired within three days of the CBCT served as additional reference. For the prostate patients, a comprehensive contour comparison of CBCT and vCT, using a trained physician's delineation, was performed. Results A high agreement of vCT and CBCT cor was found in terms of the proton range and gamma‐index analysis. For all patients and indications between 95% and 100% of the proton dose profiles in beam's eye view showed a range agreement of better than 3 mm. The pass rate in a (2%,2 mm) gamma‐comparison was between 96% and 100%. For H&N patients, an equivalent agreement of vCT and CBCT cor to the reference rpCT was observed. However, for the prostate cases, an insufficient accuracy of the vCT contours retrieved from DIR was found, while the CBCT cor contours showed very high agreement to the contours delineated on the raw CBCT. Conclusions For H&N patients, no considerable differences of vCT and CBCT cor were found. For prostate cases, despite the high dosimetric agreement, the DIR yields incorrect contours, probably due to the more pronounced anatomical changes in the abdomen and the reduced soft‐tissue contrast in the CBCT. Using the vCT as prior, these inaccuracies can be overcome and images suitable for accurate delineation and dose calculation in CBCT‐based adaptive IMPT can be retrieved from scatter correction of the CBCT projections.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here