Absolute x‐ray dosimetry on a synchrotron medical beam line with a graphite calorimeter
Author(s) -
Harty P. D.,
Lye J. E.,
Ramanathan G.,
Butler D. J.,
Hall C. J.,
Stevenson A. W.,
Johnston P. N.
Publication year - 2014
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.4870387
Subject(s) - kerma , beamline , absorbed dose , calorimeter (particle physics) , dosimetry , materials science , graphite , synchrotron , beam (structure) , collimated light , optics , nuclear physics , nuclear medicine , physics , detector , medicine , laser , composite material
Purpose: The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free‐air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line.Methods: The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x‐ray beam from the synchrotron with well‐defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross‐sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free‐air chamber were converted to absorbed dose to water using the AAPM TG‐61 protocol.Results: Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free‐air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free‐air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free‐air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%.Conclusions: The good agreement of the graphite calorimeter and free‐air chamber results indicates that both devices are performing as expected. Further investigations at higher dose rates than 50 Gy/s are planned. At higher dose rates, recombination effects for the free‐air chamber are much higher and expected to lead to much larger uncertainties. Since the graphite calorimeter does not have problems associated with dose rate, it is an appropriate primary standard detector for the synchrotron IMBL x rays and is the more accurate dosimeter for the higher dose rates expected in radiotherapy applications.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here