z-logo
Premium
MO‐D‐141‐03: Characterization of a One‐Ring Small‐Animal PET Prototype
Author(s) -
Miranda A
Publication year - 2013
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.4815250
Subject(s) - lyso , iterative reconstruction , image resolution , imaging phantom , detector , image quality , computer science , physics , optics , normalization (sociology) , computer vision , artificial intelligence , algorithm , nuclear medicine , scintillator , image (mathematics) , medicine , sociology , anthropology
Purpose: 1) To experimentally characterize a one‐ring small‐animal PET prototype currently being developed at Instituto de Fisica, UNAM. 2) To develop a software engine for data rebinning and image reconstruction from list mode raw data. Methods: The prototype detectors are an assembly of 16×16 LYSO scintillation crystals (1×1×10 mm3) coupled to position sensitive photomultiplier tubes (PS‐PMT) Hamamatsu H7546B, placed in a ring of 9.8 cm inner diameter. PS‐PMT output signals are reduced with resistive chains and digitized with a multichannel acquisition board based on FPGAs using a coincidence window of 6 ns and 12 bits encoding depth. Corrections for spatial distortions, decay, center of rotation and detector normalization have been implemented and are part of our data processing protocol. Energy resolution is measured for each individual crystal using a normalization phantom (hollow cylinder containing 18F mixed with water). Spatial resolution is measured with line sources at different radial distances. Sinograms are obtained from list mode data using different rebinning algorithms (SSRB, MSRB and FORE). Image reconstruction is performed using analytical (FBP, ART) and iterative algorithms (ML‐EM, OSEM). Data analysis and processing have been implemented in MATLAB. Results: The energy resolution of individual crystals has a typical value of 21±3% around the photopeak. The reconstructions of the line sources show different quality depending on the reconstruction technique used. Among the rebinning methods, FORE shows best results producing a spatial resolution of 1.36 mm when using FBP. FORE followed by ML‐EM iterative algorithm provides the best spatial resolution (1.05 mm), but with great computational effort. Conclusion: A one‐ring small‐animal PET prototype has been built and characterized in terms of spatial and energy resolution. Different rebinning and reconstruction methods have been successfully implemented. Future work will involve phantoms studies (microDerenzo, NEMA NU4‐2008) to determine other performance characteristics. DGAPA‐UNAM PAPIIT IN105913

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here