SU‐E‐J‐64: Landmark and ROI‐Enhancement‐Assisted Inter‐Patient Deformable Registration of 3D Bladder CT Images
Author(s) -
wang Y,
Sharp G,
Jackson A,
Saleh Z,
Apte A,
Veeraraghavan H,
Deasy J
Publication year - 2013
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.4814276
Subject(s) - sørensen–dice coefficient , region of interest , image registration , artificial intelligence , thin plate spline , computer vision , spline (mechanical) , b spline , computer science , mathematics , nuclear medicine , segmentation , medicine , image segmentation , image (mathematics) , spline interpolation , physics , mathematical analysis , bilinear interpolation , thermodynamics
Purpose: Deformable image registration (DIR) of the pelvis, and in particular, the bladder, is known to be a difficult problem. We tested several pre‐processing strategies to improve the effectiveness of registration. Methods: We studied the use of automatically‐derived landmarks (LMs) and enhanced regions of interest (ROIs) to improve existing DIR algorithms, such as B‐Spline. The three outstanding LMs in the bladder are the two ureteral orifices and the internal urethral orifice.We used 10 pelvic CT image sets with bladders of different shapes (either full or empty). Interpatient registration was performed using four Methods: 1. B‐Spline, standard intensity‐based B‐Spline registration;2. LM B‐Spline, B‐Spline registration with forced matching of corresponding landmarks;3. ROI enhancement (ROI Enh) B‐Spline, signal intensity of the bladder ROI enhanced during pre‐processing to weigh the bladder more when registering; 4. LM + ROI Enh B‐Spline. Results: 1. B‐Spline DIR resulted in poor registration due to the variance of shapes and sizes among the bladders.2. LM B‐Spline achieved the least distance between landmarks, albeit with poor Dice coefficient values and high registration uncertainty. This method is reliant on the number of landmarks. 3. ROI Enh B‐Spline achieved a higher Dice coefficient and lower registration uncertainty but larger LM distance, when compared to LM B‐Spline. This method is most applicable where ROI volume boundary alignment is sufficient. 4. LM + ROI Enh B‐Spline achieved the best Result , when taking into account of all the quantitative and qualitative measurements. In general, we observed a tradeoff between achieving a reliable bladder registration and reliable registration of other parts, such as bones. Conclusion: We developed three methods to improve DIR by combining existing approaches. For DIR of bladders, the application of LMs plus ROI Enh B‐Spline achieved the best overall results, based on quantitative results and physician opinion.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here