Observation of super‐resolution in digital breast tomosynthesis
Author(s) -
Acciavatti Raymond J.,
Maidment Andrew D. A.
Publication year - 2012
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.4757583
Subject(s) - subpixel rendering , aliasing , detector , tomosynthesis , iterative reconstruction , projection (relational algebra) , optics , image resolution , imaging phantom , fourier transform , physics , pixel , computer science , computer vision , mammography , filter (signal processing) , algorithm , medicine , cancer , quantum mechanics , breast cancer
Purpose: Digital breast tomosynthesis (DBT) is a 3D x‐ray imaging modality in which tomographic sections of the breast are generated from a limited range of tube angles. Because oblique x‐ray incidence shifts the image of an object in subpixel detector element increments with each increasing projection angle, it is demonstrated that DBT is capable of super‐resolution (i.e., subpixel resolution). Methods: By convention, DBT reconstructions are performed on planes parallel to the breast support at various depths of the breast volume. In order for resolution in each reconstructed slice to be comparable to the detector, the pixel size should match that of the detector elements; hence, the highest frequency that can be resolved in the plane of reconstruction is the alias frequency of the detector. This study considers reconstruction grids with much smaller pixelation to visualize higher frequencies. For analytical proof of super‐resolution, a theoretical framework is developed in which the reconstruction of a high frequency sinusoidal input is calculated using both simple backprojection (SBP) and filtered backprojection. To study the frequency spectrum of the reconstruction, its Fourier transform is also determined. The experimental feasibility of super‐resolution was investigated by acquiring images of a bar pattern phantom with frequencies higher than the detector alias frequency. Results: Using analytical modeling, it is shown that the central projection cannot resolve frequencies exceeding the detector alias frequency. The Fourier transform of the central projection is maximized at a lower frequency than the input as evidence of aliasing. By contrast, SBP reconstruction can resolve the input, and its Fourier transform is correctly maximized at the input frequency. Incorporating filters into the reconstruction smoothens pixelation artifacts in the spatial domain and reduces spectral leakage in the Fourier domain. It is also demonstrated that the existence of super‐resolution is dependent on position in the reconstruction and on the directionality of the input frequency. Consistent with the analytical results, experimental reconstructions of bar patterns showed visibility of frequencies greater than the detector alias frequency. Super‐resolution was present at positions predicted from analytical modeling. Conclusions: This work demonstrates the existence of super‐resolution in DBT. Super‐resolution has the potential to impact the visualization of fine structural details in the breast, such as microcalcifications and other subtle signs of cancer.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here