z-logo
Premium
Sci—Fri AM: Imaging — 02: High resolution detectors for PET mammography
Author(s) -
Cuddy SG,
Rowlands JA
Publication year - 2012
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.4740188
Subject(s) - silicon photomultiplier , lyso , scintillation , detector , optics , scintillator , physics , photodetector , breast imaging , photon , photomultiplier , optoelectronics , mammography , medicine , breast cancer , cancer
Purpose: With high specificity for malignant breast lesions, dedicated‐breast molecular imaging systems such as positron emission mammography (PEM) have potential to improve the sensitivity of cancer in women with radio‐dense breasts and to reduce the false‐positive rate of breast screening when used as a diagnostic adjunct. For high signal‐to‐noise ratio and to minimize the patient dose, scintillation detectors in a PEM system must have high annihilation photon detection efficiency. This efficiency can be increased by accepting annihilation photons from wider incident angles and by using depth‐of‐interaction (DOI) measurement within a scintillation crystal to minimize parallax blurring. We have developed a dual‐ended readout block (DERB) detector that uses asymmetry of signals from photodetectors on either end of a scintillation array to measure DOI and uses Anger Logic with light sharing to identify interacting crystal elements while minimizing the number of photodetectors required. Methods: A prototype DERB detector was constructed from two arrays of silicon photomultipliers (SiPM), two glass optical diffusers, and an array of LYSO scintillation crystals. Assembled, each of the 2 × 2 SiPM arrays detect photons that are dispersed via the optical light diffusers originating from either end of 3 × 3 scintillation crystal elements. We evaluated the ability of the detector to identify the crystal index, resolve DOI, and discriminate energy. Results: The DERB detector was able to clearly identify interacting crystal elements, to measure DOI with ̃5mm resolution in 2mm × 2mm × 20mm crystals, and to achieve an average energy resolution of ̃20%. Conclusions: The DERB detector characteristics suggest that it can be used to reduce the parallax effect in PEM systems without increasing the number of required photodetectors. Further investigation is warranted to improve performance with high optical photon detection efficiency photodetectors.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here