TH‐E‐218‐03: On the Significance of Density‐Induced Speed of Sound Variations on Ultrasound‐Guided Radiotherapy
Author(s) -
Fontanarosa D,
van der Meer S,
Bloemen E,
Verhaegen F
Publication year - 2012
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.4736389
Subject(s) - imaging phantom , speed of sound , ultrasound , scanner , rotation (mathematics) , physics , nuclear medicine , biomedical engineering , computer science , materials science , acoustics , optics , medicine , artificial intelligence
Purpose : US systems assume that speed of sound (SOS) is constant in human soft tissues (at a value of 1540 m/s), while its actual non homogeneous distribution produces small but systematic errors of up to a few millimeters in the positions of scanned structures. This work aims at showing the effect of SOS aberration on ultrasound guided radiotherapy (US‐gRT) as a function of implemented workflow. Methods : Four scenarios were considered of possible changes between simulation (SIM) and treatment (TX) stage: no changes; patient rigid rotation‐translation; probe position change; patient tissues thicknesses change. The US‐gRT workflows investigated were inter‐modality (INTER), where TX US scans are compared to SIM CT scans; intra‐modality (INTRA), where TX US scans are compared to SIM US scans; and INTERc and INTRAc where US images are corrected for SOS aberration using a SIM CT based algorithm. To simulate the effect of tissues thicknesses change experimentally, a dual layered phantom was filled with 2 cm of water (SOS 1490 m/s) first, and of 20% saline solution (SOS 1600 m/s) after, on top of 6 cm of sunflower oil (SOS 1450 m/s); the phantom was CT and US scanned, the layers thicknesses were reduced to 1 cm and 5 cm respectively, a second US scan was performed in the new configuration and the errors resulting from the different workflows were compared. Results : INTER produces in all scenarios an error proportional to SOS aberration; while INTRA and corrected workflows produce at worst errors proportional to the SOS distribution variation (ΔSOS). The dual layered phantom proved experimentally that the ΔSOS error, even when a substantial change in thicknesses is applied, is a second order effect. Conclusions : Our work suggests that a correction as the one used for this study is reasonably advantageous for all workflows and most of the clinical cases.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here