MO‐G‐213AB‐06: Segment Matching Optimization for Modulated Electron Radiation Therapy
Author(s) -
Gokhroo G,
Klein E
Publication year - 2012
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.4735843
Subject(s) - smoothing , imaging phantom , monte carlo method , computer science , dosimetry , homogeneity (statistics) , radiation , cathode ray , matching (statistics) , radiation treatment planning , code (set theory) , electron , physics , optics , radiation therapy , nuclear medicine , mathematics , computer vision , set (abstract data type) , radiology , statistics , medicine , quantum mechanics , machine learning , programming language
Purpose : Modulated electron radiotherapy (MERT) has been demonstrated to be an ideal treatment for lesions close to the surface in terms of dose coverage and sparing of underlying critical organs and normal tissues. The purpose of this study was to obtain the parameters and devise strategies for segment matching which are necessary for efficient MERT treatment planning. Methods : In this study we used EGS4nrc/BEAMnrc and MCSim code for Monte Carlo calculations. The Computational Environment for Radiotherapy research (CERR) tool was used for viewing and comparing plans. A water phantom, delineated with stepped target idealized for two segments with sizes from 2 to 6 cm and electron beam energies of 6, 9, 12, 16 and 20 MeV were used for the calculations. The variation in dose distribution with different energies of abutte electron segments and change in segment size were studied. In order to obtain homogenous dose at the segment match, various gaps and smoothing between segments were introduced. Finally, a salivary gland MERT plan was executed using the segment match optimization scheme. Results : As the energy difference between two consecutive segments increased, dose uniformity at the segment junction decreased. For small segments (< 4 cm) optimization can be improved by introducing a gap (1–2 mm) between segments. However, for larger segments, smoothing was found to be more beneficial than gapping the segments. The salivary gland case was successful in terms of dose coverage and homogeneity aided by the segment matching techniques described. Conclusions : We conclude that use of bigger segments, and smaller differences in energy for abutting segments, should be prioritized for MERT planning. This study provides an optimization regimen of segment matching for MERT treatment planning with gaps/smoothing, depending on segment size and energy in order to provide better dose coverage and expedite the forward planning process. Varian Master Research Agreement

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here