An electromagnetic navigation system for transbronchial interventions with a novel approach to respiratory motion compensation
Author(s) -
Gergel Ingmar,
Hering Jan,
Tetzlaff Ralf,
Meinzer HansPeter,
Wegner Ingmar
Publication year - 2011
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3662871
Subject(s) - compensation (psychology) , medical physics , computer science , medicine , psychology , psychoanalysis
Purpose: Bronchoscopic interventions, such as transbronchial needle aspiration (TBNA), are commonly performed procedures to diagnose and stage lung cancer. However, due to the complex structure of the lung, one of the main challenges is to find the exact position to perform a biopsy and to actually hit the biopsy target (e.g., a lesion). Today, most interventions are accompanied by fluoroscopy to verify the position of the biopsy instrument, which means additional radiation exposure for the patient and the medical staff. Furthermore, the diagnostic yield of TBNA is particularly low for peripheral lesions. Methods: To overcome these problems the authors developed an image‐guided, electromagnetic navigation system for transbronchial interventions. The system provides real time positioning information for the bronchoscope and a transbronchial biopsy instrument with only one preoperatively acquired computed tomography image. A twofold respiratory motion compensation method based on a particle filtering approach allows for guidance through the entire respiratory cycle. In order to evaluate our system, 18 transbronchial interventions were performed in seven ventilated swine lungs using a thorax phantom. Results: All tracked bronchoscope positions were corrected to the inside of the tracheobronchial tree and 80.2% matched the correct bronchus. During regular respiratory motion, the mean overall targeting error for bronchoscope tracking and TBNA needle tracking was with compensation on 10.4 ± 1.7 and 10.8 ± 3.0 mm, compared to 14.4 ± 1.9 and 13.3 ± 2.7 mm with compensation off. The mean fiducial registration error (FRE) was 4.2 ± 1.1 mm. Conclusions: The navigation system with the proposed respiratory motion compensation method allows for real time guidance during bronchoscopic interventions, and thus could increase the diagnostic yield of transbronchial biopsy.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here