SU‐E‐T‐650: Impact of Machine Output Rate on Effective Dose Rate and Biologically Equivalent Fraction Size in Total Body Irradiation (TBI)
Author(s) -
Stewart RD,
Kalet A,
Laramore GE
Publication year - 2011
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3612613
Subject(s) - fraction (chemistry) , nuclear medicine , total body irradiation , materials science , medicine , biomedical engineering , chemistry , surgery , organic chemistry , chemotherapy , cyclophosphamide
Purpose: Examine the feasibility and biological significance of increasing machine output rates in extended‐distance Total Body Irradiation (TBI). Methods: Biologically equivalent doses for TBI are derived from the LQ cell survival model. Effective dose rates and corrected fraction size for a mini‐TBI (i.e., 1 fraction × 2 Gy to patient mid‐line) delivered using 4 and 8 beams are computed as a function of machine output rate. The number of beams used for a TBI tends to increase with increasing patient size because of the clinical constraint of no more than 1000 MU per beam. All of the reported results include a 1 minute gap between beams and a (conservative) 5 minute gap for patient repositioning. Results: For a 4 beam treatment, increasing the machine output rate from 200 to 400 MU/minute reduced the fraction delivery time by 36% (28 to 18 minutes), and only increased the effective dose rate from 7 to 11 cGy/minute. For 8 beams, the fraction delivery times for 200 and 400 MU/min are 52 minutes (3.85 cGy/min) to 20 minutes (6.16 cGy/min), respectively. Increasing the machine output rate from 200 to 400 MU/min is unlikely to require more than 2–5% reduction in fraction size (alpha/beta = 1 Gy). The size of the required correction decreases as alpha/beta increases. Conclusions: Patient‐specific planning to correct for differences in beam number (patient size) are unlikely to alter the determination of biologically equivalent fraction sizes by more than 5%, which is well within the +/− 10% uniformity specified in many TBI protocols. A clinical trial to evaluate patient safety and treatment efficacy for machine output rates as high as 600–700 MU per minute are reasonable. Such a trial has the potential to substantially to increase patient comfort and reduce facility and labor costs without jeopardizing treatment effectiveness or safety.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here