Premium
SU‐E‐T‐611: Dosimetric Comparison of Helical to Standard Three Dimensional Conformal Radiation Treatment for Distal Esophageal Cancer
Author(s) -
Hu A,
Qi S,
Kavanagh B,
Schefter T
Publication year - 2011
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3612574
Subject(s) - tomotherapy , medicine , nuclear medicine , radiation treatment planning , dosimetry , esophageal cancer , radiation therapy , cancer , radiology
Purpose: At our institution distal esophageal cancer has been treated with three‐dimensioal conformal radiotherapy (3DCRT), usually with 5–9 non‐ opposing beams. Recently, TomoTherapy® introduced a helical 3DCRT (H3D) modality for faster treatment planning and delivery. The purpose of this study was to evaluate whether H3D can result in improvements over traditional 3DCRT. Methods: Ten consecutive patients with lower third esophageal adenocarcinoma treated with 3DCRT to 45 Gy (1.8 Gy/fraction for 25 fractions) were selected for a retrospective treatment planning study. 3DCRT plans were created using XIO (Version 4.4, CMS Inc, St. Louis, MO). H3D plans were generated using TomoTherapy Planning Station (Version 4.0.3, Madison, WI). As a 3D planning mode, H3D allows PTV coverage to be specified but no other optimization. PTV coverage was matched in 3DCRT and H3D plans. Jaw size of 2.5 cm and a pitch of 0.287 were used. Dose volume histograms, heterogeneity index and treatment delivery time were compared. Results: All H3D plans achieved at least 25% lower lung volume at 20 Gy (14.8%±8.3%) compared to 3DCRT plans (19.9%±9.7%). Liver V30 was 40% lower in H3D plans (11.6%±4.9% vs 17.8%±7.0%). H3D plans also lowered heart V30 by 10% (26.3% vs 30.3%) and heart V40 by 19% (15.1% vs 18.9%). Dose to 1% of cord receiving highest dose was 10% lower (31.14Gy vs 34.68Gy). The treatment time for H3D was approximately 6 minutes for an average target length of 16cm, comparable to 3DCRT. The indices where DCRT fared slightly better were lung V5(49.2% vs 64.7%), V10(39.5% vs 51.7%) and kidney V20 (10.2% vs 11.1%). Conclusions: H3D produces viable treatment plans, compared to traditional 3DCRT. H3D plans were significantly better in terms of lung V20, heart V30 & V40, maximum cord dose and liver V30. Kidney, lung V5 and V10 are slightly worse compared to 3DCRT.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom