SU‐E‐T‐508: First Clinical Commissioning of a Dynamic Gating Interface for an Electromagnetic Tracking System
Author(s) -
Santanam L,
Ge J,
Goddu S,
Parikh P
Publication year - 2011
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3612461
Subject(s) - gating , isocenter , imaging phantom , physics , optics , linear particle accelerator , computer science , beam (structure) , nuclear medicine , medicine , physiology
Purpose: Electromagnetic tracking has been used to continuously monitor intra‐fraction prostate motion. We report on the commissioning of a clinical electromagnetic tracking system with linear accelerator gating (DynamicEdge™GatingInterface, Calypso Medical Technologies, WA). Methods: Routinely, the motion of the Varian Respiratory Position Management(RPM) block, an external surrogate, is used for gating. With the Dynamic Gating Interface(DGI), the positions of the internal transponders implanted in the tumor are used for gating. The gating limits, defined as +/− thresholds in all three axes around the machine isocenter, define the beam on/off boundary, with a beam hold when the limit is exceeded. An in‐house developed 4D stage and a fixture containing three radiofrequency transponders were used for measurements. Beam stability, IMRT dose verification and latency were measured. The 4D stage was set to move in a repetitive sinusoidal pattern with peak amplitude of 1cm at 15 cycles per minute. For beam stability, the charge for non‐gated vs gated beam delivery was compared. For IMRT dose verification, a solid water phantom with films sandwiched between planes was used. A gating window (±0.2cm) was set for all five IMRT plans and gated dosimetric accuracy compared to static delivery. For latency measurements, a series of gated lateral MV integrated images were taken at an acquisition rate of 1fps. By knowing the actual motion trajectory measured with electromagnetic tracking, one can compare the trajectory of the gated integrated image to obtain latency. Results: The output stability for gated vs non‐gated fields was within 1%. For IMRT fields, on average 90% of the points passed the 3% dose, 3mm DTA criteria. The average system latency was measured to be within 281ms. Conclusions: The DGI has been commissioned and is being used clinically for prostate cancer patients to manage intra‐fraction motion. The latency may not currently be optimized for tumor sites exhibiting respiratory motion.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here