SU‐E‐I‐192: Improved High‐Resolution Imaging through an Aneurysm Coil Mass Using the MAF Compared with a Flat Panel Detector
Author(s) -
Jain A,
Panse A,
Ionita C,
Singh V,
Rudin S,
Bednarek D
Publication year - 2011
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3611766
Subject(s) - imaging phantom , electromagnetic coil , flat panel detector , detector , neurovascular bundle , materials science , image resolution , pixel , projection (relational algebra) , optics , biomedical engineering , nuclear medicine , computer science , physics , medicine , anatomy , algorithm , quantum mechanics
Purpose: To compare the ability of a standard flat panel detector (FPD) with that of the new Microangiographic Fluoroscope (MAF) to visualize individual coils used in minimally invasive (endovascular) treatment of cerebro‐vascular aneurysms where high‐resolution image guidance may be critical to the accuracy and hence outcome of the intervention. Methods: A human neurovascular aneurysm elastomer phantom was filled with standard platinum coils (GDC‐10 Coil SR) and placed on an anthropomorphic head phantom to provide a realistic challenge to the two detectors, both of which were mounted on a Toshiba Infinix C‐arm gantry. The standard FPD (Varian PaxScan‐2020, 194μm pixel‐width, 600μm thick CsI) was compared with a custom MAF (35μm pixel‐width and 300μm thick CsI‐HR type). Using the same x‐ray technique parameters for the same projection view, the images from each detector were digitally contrast matched to enable comparisons of important features such as individual coils and unfilled spaces within the coil mass both for overall qualitative detail and for quantitative measures of corresponding profiles across the features. Results: The FPD images gave an overall impression of being blurred compared to the MAF images where more individual coils and a clearer demarcation of the spaces between the coils were apparent. The ratio of the average individual coil wire diameter taken from four separate profiles for the FPD to that for the MAF was 1.22, indicating a substantial improvement in detail visualization for the MAF. Conclusions: Standard FPDs have difficulty separating coil wires and visualizing through dense aneurysm coil masses whereas the MAF with its large adjustable dynamic gain and high spatial resolution provides improved visualization and should be able to provide superior image guidance during delicate neurovascular interventions. Support‐NIH Grants R01‐EB008425, R01‐EB002873.