CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter
Author(s) -
Basran Parminder S.,
Robertson Andrew,
Wells Derek
Publication year - 2011
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3539648
Subject(s) - imaging phantom , voxel , contrast to noise ratio , standard deviation , nuclear medicine , brachytherapy , image quality , hounsfield scale , reconstruction filter , streak , filter (signal processing) , artifact (error) , medicine , mathematics , computer science , radiology , artificial intelligence , computed tomography , physics , computer vision , filter design , radiation therapy , optics , image (mathematics) , statistics , root raised cosine filter
Purpose: To design a postprocessing 3D adaptive median filter that minimizes streak artifacts and improves soft‐tissue contrast in postoperative CT images of brachytherapy seed implantations. Methods: The filter works by identifying voxels that are likely streaks and estimating more reflective voxel intensity by using voxel intensities in adjacent CT slices and applying a median filter over voxels not identified as seeds. Median values are computed over a 5 × 5 × 5 mm region of interest (ROI) within the CT volume. An acrylic phantom simulating a clinical seed implant arrangement and containing nonradioactive seeds was created. Low contrast subvolumes of tissuelike material were also embedded in the phantom. Pre‐ and postprocessed image quality metrics were compared using the standard deviation of ROIs between the seeds, the CT numbers of low contrast ROIs embedded within the phantom, the signal to noise ratio (SNR), and the contrast to noise ratio (CNR) of the low contrast ROIs. The method was demonstrated with a clinical postimplant CT dataset. Results: After the filter was applied, the standard deviation of CT values in streak artifact regions was significantly reduced from 76.5 to 7.2 HU. Within the observable low contrast plugs, the mean of all ROI standard deviations was significantly reduced from 60.5 to 3.9 HU, SNR significantly increased from 2.3 to 22.4, and CNR significantly increased from 0.2 to 4.1 (all P < 0.01 ). The mean CT in the low contrast plugs remained within 5 HU of the original values. Conclusion: An efficient postprocessing filter that does not require access to projection data, which can be applied irrespective of CT scan parameters has been developed, provided the slice thickness and spacing is 3 mm or less.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here