z-logo
Premium
MO‐EE‐A3‐06: First Clinical Results of 3D Verification of Volumetric‐Modulated Arc Therapy (VMAT) of Prostate and Lung Cancer Patients Using EPID Dosimetry
Author(s) -
Mijnheer B,
Mans A,
OlacireguiRuiz I,
Sonke J,
Stroom J,
Tielenburg R,
Herk M,
Vijlbrief R
Publication year - 2010
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3469096
Subject(s) - nuclear medicine , medicine , prostate cancer , imaging phantom , dosimetry , image guided radiation therapy , prostate , lung cancer , radiation therapy , radiation treatment planning , in vivo , cancer , radiology , oncology , microbiology and biotechnology , biology
Purpose : To evaluate the first clinical results of 3D verification of volumetric‐modulated arc therapy (VMAT) of prostate and lung cancer patients using EPID dosimetry, both pre‐treatment and in vivo . Method and Materials : EPID images obtained during VMAT delivery using gantry‐angle resolved data acquisition are converted to 3D dose distributions inside a phantom or patient using a back‐projection model. In addition to verification of the dose at the isocentre, 3D gamma analysis is performed to compare planned and EPID‐reconstructed 3D VMAT dose distributions. Gamma evaluation parameters are mean and maximum (1%) gamma and % gamma < 1. Results : VMAT plans of 10 prostate and 10 lung cancer patients, verified by means of 3D EPID dosimetry, have been analysed. The average difference of the dose at the isocentre was for prostate cancer VMAT (−0.2±1.6)% and (+0.4±1.6)%, pre‐treatment and in vivo , respectively, and for the hypofractionated lung cancer VMAT plans (+2.0±1.2)% and (−0.7±2.3)%. 3D gamma evaluation showed almost the same results for pre‐treatment and in vivo verification of the 3D dose distribution for prostate cancer VMAT. For instance, the average of the mean gamma values of all patients is (0.42±0.12)% and (0.48±0.06)% for the pre‐treatment and in vivo results, respectively. Larger deviations have been observed for lung cancer VMAT verification; e.g. the average of the mean gamma values of all patients is (0.41±0.03)% for pre‐treatment verification, and (0.68±0.27)% for the in vivo results. Conclusion : The results of this study show that EPID dosimetry is a valuable tool for 3D verification of VMAT delivery, both pre‐treatment and in vivo . More clinical data are needed to assess acceptance criteria for 3D gamma evaluation of VMAT verification. Conflict of Interest : Research sponsored by Elekta Oncology Systems Corporation.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here