z-logo
Premium
SU‐GG‐I‐154: Evaluation of Quantitative Potential of Breast Tomosynthesis Using a Voxelized Anthropomorphic Breast Phantom
Author(s) -
Mehtaji D,
Shafer C,
Chen B,
Lo J
Publication year - 2010
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3468190
Subject(s) - imaging phantom , voxel , tomosynthesis , thresholding , nuclear medicine , breast imaging , mammography , breast density , projection (relational algebra) , computer science , artificial intelligence , mathematics , breast cancer , medicine , image (mathematics) , algorithm , cancer
Purpose : To assess the quantitative potential of breast tomosynthesis by estimating the percent density of voxelized anthropomorphic breast phantoms. Method and Materials : A Siemens breast tomosynthesis system was modeled using Monte Carlo methods and a voxelized anthropomorphic breast phantom. The images generated by the simulation were reconstructed using Siemens filtered back‐projection software. The non‐uniform background due to scatter, heel effect, and limited angular sampling was estimated by simulating and subtracting images of a uniform 100% fatty breast phantom. To estimate the density of each slice, the total number of fatty and glandular voxels was calculated both before and after applying a thresholding algorithm to classify voxels as fat vs. glandular. Finally, the estimated density of the reconstructed slice was compared to the known percent density of the corresponding slice from the voxelized phantom. This percent density estimation comparison was done for a 30%‐ and a 60%‐ dense 5cm breast phantom. Results : Without thresholding, overall density estimation errors for the central eleven slices were 0.64% and 2.1% for the 30% and 60% dense phantoms, respectively. After thresholding to classify voxels as fat vs. glandular, errors for central eleven were 3.5% and 6.2%, respectively. Voxel to voxel matching of the phantom vs. reconstructed slice demonstrated 80.3% and 73.08% respectively of voxels were correctly classified. Conclusion : The errors in slice density estimation were within 10% for both the phantoms thus implying that quantification of breast density using tomosynthesis is possible. However, limitations of the acquisition and reconstruction process continue to pose challenges in density estimation leading to potential voxel to voxel errors that warrant further investigation. Conflict of Interest: Joseph Lo: research grant and consultant, Siemens Healthcare.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here