z-logo
Premium
SU‐GG‐I‐39: Evaluation of Different Benchmark Measurements for Validating Monte Carlo MDCT Source Models Used in Estimating Radiation Dose
Author(s) -
Turner A,
McNittGray M
Publication year - 2010
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3468072
Subject(s) - monte carlo method , scanner , benchmark (surveying) , computer science , nuclear medicine , physics , optics , mathematics , statistics , medicine , geodesy , geography
Purpose : Monte Carlo simulation has become a popular method of estimating dose from multidetector computed tomography (MDCT) exams. Typically, MDCT modeling techniques and scanner‐specific input information are validated using physical dose measurements made under very simple conditions, such as homogenous cylindrical phantoms (i.e. CTDI). The purpose of this study is to investigate the sensitivity of such measurements in order to assess their utility in validating scanner‐specific x‐ray source information used in MDCT simulation packages. Method and Materials : Two 64‐slice MDCT scanners were used to obtain three types of benchmark measurements: 1) half and quarter value layers (HVL/QVL), 2) bowtie profiles (exposure values across the fan‐beam), and 3) CTDI 100 values. Analogous Monte Carlo simulations were performed using two types of x‐ray source models; (A) one based on physical measurements and (B) one based on information provided from other sources. Results : HVL/QVL simulations using source model A resulted in average disagreements of 8.1% and 10.5% for Scanners 1 and 2, respectively, while source model B had errors of 2.2% and 39.8%. Similarly, bowtie profile simulations had average errors of 0.7% and 4.0% for source model A and 5.3% and 19.4% for source model B. Finally, CTDI 100 simulation errors were 1.3% and 3.5% for source model A and 4.1% and 34.9% for source model B. Conclusion : The results show that the errors between measurements and simulations for the HVL/QVL and bowtie profile measurements reveal more fundamental and specific information about the accuracy of source models than does CTDI 100 . This implies that CTDI 100 may not be as sensitive as more elemental measurements for verifying the accuracy of more complicated dose simulations. This study shows that while CTDI 100 may be a necessary benchmark it is not sufficient for MDCT Monte Carlo dosimetry validation. Further testing in heterogeneous phantoms is needed to extend these sensitivity evaluations.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here