z-logo
Premium
Measurement of absorbed dose, quality factor, and dose equivalent in water phantom outside of the irradiation field in passive carbon‐ion and proton radiotherapies
Author(s) -
Yonai Shunsuke,
Kase Yuki,
Matsufuji Naruhiro,
Kanai Tatsuaki,
Nishio Teiji,
Namba Masao,
Yamashita Wataru
Publication year - 2010
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3458721
Subject(s) - imaging phantom , absorbed dose , dosimetry , irradiation , equivalent dose , proton , physics , nuclear medicine , radiochemistry , materials science , medical physics , nuclear physics , optics , chemistry , medicine
Purpose: Successful results in carbon‐ion and proton radiotherapies can extend patients’ lives and thus present a treatment option for younger patients; however, the undesired exposure to normal tissues outside the treatment volume is a concern. Organ‐specific information on the absorbed dose and the biological effectiveness in the patient is essential for assessing the risk, but experimental dose assessment has seldom been done. In this study, absorbed doses, quality factors, and dose equivalents in water phantom outside of the irradiation field were determined based on lineal energy distributions measured with a commercial tissue equivalent proportional counter (TEPC) at passive carbon‐ion and proton radiotherapy facilities. Methods: Measurements at eight positions in the water phantom were carried out at the Heavy‐Ion Medical Accelerator in Chiba of the National Institute of Radiological Sciences for 400 and 290 MeV/u carbon beams and at the National Cancer Center Hospital East for a 235 MeV proton beam. Results: The dose equivalent per treatment absorbed dose at the center of the range‐modulated region H / D tdecreased as the position became farther from the beam axis and farther from the phantom surface. The values of H / D tranged from 6.7 to 0.16 mSv/Gy for the 400 MeV/u carbon beam, from 1.3 to 0.055 mSv/Gy for the 290 MeV/u carbon beam, and from 4.7 to 0.24 mSv/Gy for the 235 MeV proton beam. The values of the dose‐averaged quality factorQ Dranged from 2.4 to 4.6 for the 400 MeV/u beam, from 2.8 to 5.3 for the 290 MeV/u beam, and from 5.1 to 8.2 for the proton beam. The authors also observed differences in the distributions of H / D tandQ Dbetween the carbon and proton beams. Conclusions: The authors experimentally obtained absorbed doses, dose‐averaged quality factors, and dose equivalents in water phantom outside of the irradiation field in passive carbon‐ion and proton radiotherapies with TEPC. These data are very useful for estimating the risk of secondary cancer after receiving passive radiotherapies and for verifying Monte Carlo calculations.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here