z-logo
Premium
Modulator design for x‐ray scatter correction using primary modulation: Material selection
Author(s) -
Gao Hewei,
Zhu Lei,
Fahrig Rebecca
Publication year - 2010
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3457472
Subject(s) - optics , detector , beam (structure) , transmission (telecommunications) , physics , materials science , computer science , telecommunications
Purpose: An optimal material selection for primary modulator is proposed in order to minimize beam hardening of the modulator in x‐ray cone‐beam computed tomography (CBCT). Recently, a measurement‐based scatter correction method using primary modulation has been developed and experimentally verified. In the practical implementation, beam hardening of the modulator blocker is a limiting factor because it causes inconsistency in the primary signal and therefore degrades the accuracy of scatter correction. Methods: This inconsistency can be purposely assigned to the effective transmission factor of the modulator whose variation as a function of object filtration represents the magnitude of beam hardening of the modulator. In this work, the authors show that the variation reaches a minimum when the K ‐edge of the modulator material is near the mean energy of the system spectrum. Accordingly, an optimal material selection can be carried out in three steps. First, estimate and evaluate the polychromatic spectrum for a given x‐ray system including both source and detector; second, calculate the mean energy of the spectrum and decide the candidate materials whose K ‐edge energies are near the mean energy; third, select the optimal material from the candidates after considering both the magnitude of beam hardening and the physical and chemical properties. Results: A tabletop x‐ray CBCT system operated at 120 kVp is used to validate the material selection method in both simulations and experiments, from which the optimal material for this x‐ray system is then chosen. With the transmission factor initially being 0.905 and 0.818, simulations show that erbium provides the least amount of variation as a function of object filtrations (maximum variations are 2.2% and 4.3%, respectively, only one‐third of that for copper). With different combinations of aluminum and copper filtrations (simulating a range of object thicknesses), measured overall variations are 2.5%, 1.0%, and 8.6% for 25.4 μ m of copper, erbium, and tungsten, respectively. With and without 300 μ m of copper in the beam, the measured variations for 25.4 μ m of copper, erbium, and tungsten, 1 mm of aluminum, as well as 406 μ m of copper, are 1.8%, 0.2%, 5.5%, 1.9%, and 7.5%, respectively. Conclusions: The spatial variation in the effective transmission factor of the modulator blocker due to beam hardening caused by the modulator itself reaches a minimum when the K ‐edge of the modulator material is near the mean energy of the spectrum. An optimal modulator material selection using the K ‐edge discontinuity is therefore proposed.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here