z-logo
Premium
Evaluation of high‐energy brachytherapy source electronic disequilibrium and dose from emitted electrons
Author(s) -
Ballester Facundo,
Granero Domingo,
PérezCalatayud José,
Melhus Christopher S.,
Rivard Mark J.
Publication year - 2009
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3194754
Subject(s) - bremsstrahlung , physics , electron , monte carlo method , atomic physics , kerma , photon , dosimetry , computational physics , nuclear physics , nuclear medicine , optics , medicine , statistics , mathematics
Purpose: The region of electronic disequilibrium near photon‐emitting brachytherapy sources of high‐energy radionuclides ( C60 o ,C137 s ,I192 r , andY169 b ) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; sourceβ − , Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, theI192 r mHDR‐v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for C60 o ,C137 s ,I192 r , andY169 b at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% forC60 o andI192 r , respectively. Electron emissions become important (i.e., > 0.5 % ) within 3.3 mm ofC60 o and 1.7 mm ofI192 r sources, yet are negligible over all distances forC137 s andY169 b . Electronic equilibrium conditions along the transversal source axis for the mHDR‐v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here