z-logo
Premium
SU‐GG‐BRC‐10: Shape Matters: Utilization of a Conformal Voxel Technique to Acquire Robust in Vivo Prostate MRSI at Short Echo Times
Author(s) -
Venugopal N,
McCurdy B,
Drachenberg Darrel,
Al Mehairi Salem,
Alamri Aziz,
Sandhu GS,
Sivalingam Sri,
Ryner Lawrence
Publication year - 2009
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3182186
Subject(s) - voxel , prostate , magnetic resonance spectroscopic imaging , scanner , pulse sequence , nuclear medicine , in vivo , nuclear magnetic resonance , materials science , magnetic resonance imaging , biomedical engineering , computer science , physics , medicine , artificial intelligence , radiology , microbiology and biotechnology , cancer , biology
Purpose: We seek to improve the quality of in vivo prostate MRSI data acquisition by utilizing an optimized conformal voxel technique coupled with a spatial‐spectral excitation PRESS pulse sequence for short echo time acquisitions. Method and Materials: All subjects were scanned on a GE 1.5T Signa MR scanner equipped with Echospeed gradients. A standard endorectal coil in combination with a torso phased‐array coil was used. The PRESS pulse sequence was modified to include the optimized conformal voxel MR spectroscopic imaging technique (CV‐MRS). This method uses up to twenty Very Selective Saturation (VSS) pulses, automatically positioned in three dimensions, to “conform” the excitation volume to the shape of the prostate, effectively nulling signal from periprostatic lipids. Subjects were scanned using both the standard PRESS and the optimized CV‐MRS techniques at long and short echo times (TE). In vivo prostate spectra were collected and processed using a modified version of LCModel. Results: We observed an average lipid reduction of 60±18% for 17 subjects over the entire prostate when using the optimized CV‐MRS technique as compared to standard MRSI techniques. In specific regions along the peripheral zone, we observed lipid reduction greater than 95%. The effect of reducing the lipid contamination has resulted in a ∼70% improvement in peak identification of key prostate metabolites, based on goodness‐of‐fit parameters. Furthermore, short TE acquisitions have resulted in a substantial increase in the citrate signal, full visualization of the citrate multiplet and other metabolites not seen at long echo times. Conclusion: In vivo implementation of this optimized MRSI technique has confirmed the reduction in peripheral lipid contamination, and improved the quality of spectra throughout the prostate. Furthermore, this is the first demonstration of short TE in vivo prostate MRSI acquisitions, which provides significant signal increase and reveal short TE metabolites to potentially improve prostate cancer detection.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here