SU‐FF‐I‐08: Ramping and Overscanning Contributions to Patient Dose in Helical CT
Author(s) -
Tien C,
Winslow J,
Hintenlang D
Publication year - 2009
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.3181127
Subject(s) - collimated light , scanner , dosimeter , materials science , nuclear medicine , dosimetry , rotation (mathematics) , optics , beam (structure) , multislice , physics , medicine , mathematics , laser , geometry
Purpose: In helical computed tomography (CT) scans, slices adjacent to the clinical volume of interest, known as z overscanning lengths, are acquired for reconstruction. Additionally, CT machines undergo a transient power state, known as tube ramping, to reach full power. This investigation will characterize the dependence of tube ramping time and z overscanning length on pitch, rotation time, beam collimation, and reconstruction slice width. These relationships will be utilized to determine the contributions to patient dose. Methods and Materials: A real‐time fiber optic coupled dosimetry system with 10 ms temporal resolution is interfaced with three organic scintillators with 0.157 mm 3 volumes. A Siemens Somatom Sensation 16 multislice helical CT scanner is used for the study with pitches varying from 0.5 to 1.5; rotation speeds between 0.5 and 1.5 seconds per rotation; reconstructed slice widths of 2.0 to 10.0 mm; and beam collimation of either 12 or 24 mm. One dosimeter remains stationary while two dosimeters are translated through the beam to provide real‐time profiles of the x‐ray field. Results: The ramping time was found to be independent of pitch and represented 0.5% of the total scan time. The z overscanning length was found to be monotonically increasing with pitch and represents anywhere from 14.3% to 35.9% of the total scan length. Conclusions: While ramping time remained constant, it has been demonstrated that z overscanning length is heavily dependent upon pitch — a high pitch added 7.1 cm to a 20.3 cm clinical scan length. Both z overscanning and ramping time must be taken into consideration when planning and managing patient dose. The effect of rotation time, beam collimation, and reconstruction slice width on ramping time and z overscanning length will be investigated in future work.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here