TH‐D‐AUD A‐04: Experimental Study of Neutron Dose Equivalent in a Proton Treatment Facility
Author(s) -
Wang X,
Gillin M
Publication year - 2008
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2962897
Subject(s) - sobp , neutron , isocenter , proton therapy , proton , dosimeter , bragg peak , physics , neutron temperature , equivalent dose , dosimetry , nuclear physics , dose profile , optics , beam (structure) , nuclear medicine , radiation , imaging phantom , medicine
Purpose: To characterize neutron dose equivalent per proton Gray (H/D) as a function of proton energy, spread‐out Bragg peak (SOBP) and aperture size at a clinical proton treatment facility using both active and passive neutron detection instruments, and to evaluate the performance of the instruments for a possible candidate for routine patient neutron exposure monitoring. Method and Materials: The H/D were measured at 2 locations near isocenter, namely in proton field but 2 cm out of range and approximately 20 cm out of field, with neutron instruments of various types. Two types of rem‐meters were used, the REM‐500, a tissue equivalent proportional counter and SWENDI‐2, a wide energy (up to 5GeV) neutron probe. The passive detectors consist of Neutrak® 144 Fast, Intermediate and Thermal Neutron Dosimeters, an etched‐track detector, and two flavors of bubble detector, BDS®, a spectrometer, and BD‐PND®. The results from these instruments were compared for 200 MeV and 160 MeV beam configurations. REM‐500 and Neutrak® were used to study the dependency of H/D on proton energy, SOBP and aperture size. Results: Various instruments had comparable H/D measurements at the out field location but varies more at the in field location. The H/D value increased linearly with proton energy, with a factor of ∼6 from 100 MeV to 250 MeV for medium snout. The H/D value increased ∼50% with increasing SOBP from 2 cm to the maximum of clinical allowed value and had a small decrease with aperture size. Conclusion: The measured results show H/D increases strongly with proton energy, moderately with SOBP, and has minimal dependence on aperture size. This is consistent with the simulation results. The Neutrak® etched‐track detector is a good candidate for patient neutron exposure monitoring due to its small size, excellent dose range, good energy range and commercial support.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here