WE‐E‐AUD B‐01: Accuracy of the Monte Carlo Dose Calculation Algorithm for Cyberknife Treatment of Small Lung Lesions
Author(s) -
Hol M,
Marijnissen JPA,
van der Baan P,
Heijmen BJM
Publication year - 2008
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2962775
Subject(s) - imaging phantom , monte carlo method , cyberknife , nuclear medicine , physics , beam (structure) , materials science , dosimetry , optics , radiosurgery , medicine , mathematics , radiation therapy , radiology , statistics
Purpose: To assess the accuracy of dose calculations for Cyberknife treatment of small lung tumors, performed with the Monte Carlo Dose Calculation algorithm (Multiplan v2.1 and later). Method and Materials: Verification measurements were performed in slab phantoms and in a newly constructed anthropomorphic thorax phantom, both made tissue equivalent materials (Gammex RMI). The modular thorax phantom can be configured with spherical Solid Water tumors of 10, 20 or 30 mm in diameter, embedded in lung tissue equivalent material. Measurements were mainly performed with Gafchromic EBT film, complemented with single point diode measurements. Single beam experiments were performed for various slab phantoms for cones of 5, 10, 20 and 60 mm beam diameter. Monte Carlo calculations were also compared with the simpler ray tracing dose calculation algorithm also available in MultiPlan. Results: Gafchromic EBT film measurements and Monte Carlo calculations for single beam irradiations of homogeneous slab phantoms were in excellent agreement with water phantom measurements and the ray tracing algorithm predictions. This proved that (1) our beam data was correctly modeled in the Monte Carlo algorithm, and (2) the Gafchromic EBT film was suitable for further experiments. For inhomogeneous slab phantoms, Monte Carlo calculated absolute doses generally agreed within 3% with measurements, even for the smallest field (5 mm). For the ray tracing algorithm, large deviations of up to 45% in the dose re‐build area in tumor behind lung were observed. Also for the 3 solid lung tumors in the thorax phantom, Monte Carlo dose calculations were in excellent agreement with measurements, while with the ray tracing algorithm high dose areas were over‐predicted both in size and in dose. Conclusion: Excellent agreement was found between Monte Carlo and measurements in inhomogeneous (anthropomorphic) phantoms. For treatment of (small) lung tumors Monte Carlo is the preferred dose calculation engine.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here