z-logo
Premium
SU‐GG‐T‐423: Radiobiological Comparison of Helical Tomotherapy and MLC‐Based IMRT for Brain and Cranio‐Spinal Tumors
Author(s) -
Esquivel C,
Mavroidis P,
Shi C,
Ferreira B,
Lind B,
Gutiérrez A,
Stathakis S,
Papanikolaou N
Publication year - 2008
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2962171
Subject(s) - tomotherapy , nuclear medicine , limiting , radiation treatment planning , medicine , radiation therapy , radiosurgery , medical physics , radiology , mechanical engineering , engineering
Purpose: In order to estimate better the clinical effectiveness of the Helical Tomotherapy and MLC‐based IMRT radiation modalities a radiobiological assessment was performed. This was achieved by employing additional physical and radiobiological criteria. Method and Materials: Two brain and cranio‐spinal cancers were investigated. For each cancer type, a linac MLC‐based step‐and‐shoot IMRT plan and a Helical Tomotherapy plan were developed. The treatment plans of the MLC‐based IMRT were developed on the Philips treatment planning station (Pinnacle 7.6 software release), whereas the dedicated Tomotherapy treatment planning station was used for the HT plans. The different treatment plans were compared using dosimetric criteria and the biologically effective uniform dose (BEUD) together with the complication‐free tumor control probability ( P + ). Results: The applied plan evaluation method shows that in the brain cancer case the HT treatment gives similar results with the MLC‐based IMRT ( P + of 66.0% and 63.4%, respectively). The total control probabilities, P B are 79.5% and 76.6%, whereas the total complication probabilities, P I are 13.4% and 13.1%. In both cases, the dose limiting tissue is the Speech Area. In the cranio‐spinal cancer case, the HT treatment plan is much better than the MLC‐based IMRT plan with P + values of 84.1% and 28.4%, respectively. The P B values are 86.4% and 51.3%, whereas the P I values are 2.3% and 23.0%. In the case of HT, the lung is the dose limiting tissue (1.7%) whereas in the case of MLC‐based IMRT the dose limiting tissues are the lung (8.1%) and the left kidney (14.2%). Conclusion: Both MLC based‐IMRT and HT are suitable for treating often large PTVs while minimizing the volume of the organs at risk receiving high dose. However, in certain more complex clinical cases the HT radiation modality may show clearly better properties in producing very conformal and clinically effective dose distributions.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here