TH‐E‐AUD‐04: Determination of Exit Skin Dose for MammoSite(R) RTS with TLD
Author(s) -
Raffi J,
DeWerd L,
Micka J,
Kunugi K
Publication year - 2007
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2761768
Subject(s) - thermoluminescent dosimeter , dosimeter , nuclear medicine , imaging phantom , dosimetry , materials science , monte carlo method , dose profile , medicine , biomedical engineering , mathematics , statistics
Purpose: To accurately determine the exit skin dose from MammoSite® Radiation Therapy System treatments using thermoluminescent dosimeters (TLDs) placed on the surface of the skin during each treatment fraction. Methods and Materials: Well‐characterized TLD‐100 chips were calibrated using137 Cs to establish an energy response correction factor for192 Ir measurements. TLD response vs. material thickness was measured and compared for thicknesses of Virtual Water™ and breast‐equivalent material from 2 to 10cm. Monte Carlo simulations were performed to determine the relationship between the dose to TLD and dose to basal skin layer for a range of treatment parameters (size and content of balloon, distance from skin, etc). Treatment planning system (TPS) predicted skin doses were also compared to the TLD measured skin dose for 29 patients and two phantom setups. Results: The TLD‐100 energy response for192 Ir relative to137 Cs was determined to be 1.045. The TL vs. thickness curves for Virtual Water™ and breast‐equivalent material were found to be within 2.5% for all thicknesses studied for192 Ir , and can be used interchangeably within the 2.5% limit, which falls within our measurement uncertainty of 3%. The Monte Carlo calculated dose to TLD agreed with the 1/r 2 corrected basal skin dose to within 0.5% for the entire range of treatment parameters studied when the dose to TLD vs. dose to water correction factor of 1.2 was applied. TPS predicted doses overestimated the TLD measured skin dose by an average of 26% for the group of 29 patients studied, and by an average of 40% for the two phantom setups. Conclusions: TLDs placed on the surface of the breast during MammoSite RTS treatments can accurately measure the skin dose when the proper correction factors are applied. The TLD measured dose is much more accurate than the TPS predicted dose.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here