SU‐FF‐J‐110: Gel Dosimetry for Measuring a Complex 3D Dose Distribution in Stereotactic Radiosurgery
Author(s) -
Whitney H,
Ding G,
Coffey C,
Gore J
Publication year - 2007
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2760615
Subject(s) - dosimetry , radiosurgery , imaging phantom , dosimeter , nuclear medicine , multileaf collimator , materials science , scanner , medical imaging , collimator , linear particle accelerator , optics , physics , beam (structure) , medicine , radiation therapy , radiology
Purpose: To explore the feasibility and the accuracy of using polymer gel dosimeters in measuring a complex 3D dose distribution irradiated using dynamic arc for stereotactic radiotherapy. Method and Materials: MAGIC‐2 polymer gel was produced and poured into a 500mL vessel. The treatment plan has four dynamic arcs and was generated from the BrainLab planning system using CT images with 6 MV photon beam. The treatment plan with a complex 3D dose distribution was delivered to gel with the micro‐multileaf collimator, m3, adapted to a Varian Trilogy treatment machine. The irradiated gel was imaged by MRI on a Philips Achieva scanner at 3T. Before imaging, the gel was placed in the imaging suite overnight to reach room temperature. The gel phantom was scanned using a multi‐echo spin‐echo sequence. T2 (transverse relaxation time) images were calculated by performing a least‐square fit to a single exponential for each pixel of the echo images. R2 (transverse relaxation rate) images were calculated as the inverse of the T2 images. A 2‐mm transverse slice through the gel at maximum dose was chosen for analysis. Results: The calculated and measured relative dose distributions were quantitatively compared using gamma index calculations. With criteria of 5% dose and 3mm distance‐to‐agreement, approximately 97% of all pixels within the 50% isodose curves in the R2 image of the plan had gamma values of less than unity, indicating that they were in acceptable agreement with the dose distribution. For criteria of 5% dose and 1 mm distance‐to‐agreement, approximately 58% of the pixels had a gamma value of less than unity. Conclusion: Polymer gel dosimetry is potentially a very useful dosimeter in measuring a complex 3D dose distribution for stereotactic radiotherapy treatment. It is able to provide a high resolution 3D dose distribution to verify a complex treatment plan.