SU‐FF‐J‐110: Gel Dosimetry for Measuring a Complex 3D Dose Distribution in Stereotactic Radiosurgery
Author(s) -
Whitney H,
Ding G,
Coffey C,
Gore J
Publication year - 2007
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2760615
Subject(s) - dosimetry , radiosurgery , imaging phantom , dosimeter , nuclear medicine , multileaf collimator , materials science , scanner , medical imaging , collimator , linear particle accelerator , optics , physics , beam (structure) , medicine , radiation therapy , radiology
Purpose: To explore the feasibility and the accuracy of using polymer gel dosimeters in measuring a complex 3D dose distribution irradiated using dynamic arc for stereotactic radiotherapy. Method and Materials: MAGIC‐2 polymer gel was produced and poured into a 500mL vessel. The treatment plan has four dynamic arcs and was generated from the BrainLab planning system using CT images with 6 MV photon beam. The treatment plan with a complex 3D dose distribution was delivered to gel with the micro‐multileaf collimator, m3, adapted to a Varian Trilogy treatment machine. The irradiated gel was imaged by MRI on a Philips Achieva scanner at 3T. Before imaging, the gel was placed in the imaging suite overnight to reach room temperature. The gel phantom was scanned using a multi‐echo spin‐echo sequence. T2 (transverse relaxation time) images were calculated by performing a least‐square fit to a single exponential for each pixel of the echo images. R2 (transverse relaxation rate) images were calculated as the inverse of the T2 images. A 2‐mm transverse slice through the gel at maximum dose was chosen for analysis. Results: The calculated and measured relative dose distributions were quantitatively compared using gamma index calculations. With criteria of 5% dose and 3mm distance‐to‐agreement, approximately 97% of all pixels within the 50% isodose curves in the R2 image of the plan had gamma values of less than unity, indicating that they were in acceptable agreement with the dose distribution. For criteria of 5% dose and 1 mm distance‐to‐agreement, approximately 58% of the pixels had a gamma value of less than unity. Conclusion: Polymer gel dosimetry is potentially a very useful dosimeter in measuring a complex 3D dose distribution for stereotactic radiotherapy treatment. It is able to provide a high resolution 3D dose distribution to verify a complex treatment plan.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom