z-logo
Premium
SU‐FF‐I‐117: System Quantification for Micro CT
Author(s) -
Tu S,
Chao T,
Lee C
Publication year - 2007
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2760493
Subject(s) - monte carlo method , randomness , kernel (algebra) , quantum noise , noise (video) , computer science , algorithm , iterative reconstruction , imaging phantom , point spread function , image quality , optics , physics , mathematics , artificial intelligence , image (mathematics) , statistics , quantum mechanics , combinatorics , quantum
Purpose: To report our efforts of the development for the software tool with the latest parallel computing techniques to characterize the various physical properties for the micro CT. Method and Materials: Various physical aspects in the micro CT imager were investigated with the strategies of mathematical modeling and computer simulation. The simulated elements included were the x‐ray focal spot blurring, scattering kernel, point spread function, quantum noise, detector blurring, and system noise. The projections of the mathematical phantoms were analytically calculated using the Radon transform formalism. Simulated noises were then added to those projection images and the final images were obtained from the image reconstruction algorithms including the exact, approximate, and iterative methods. A dedicated random number generator for the noise simulation was developed to produce un‐correlated random number sequences. A randomness test of the intra‐ and inter‐correlation for the random number sequences was also developed to validate the quality of noise simulation. The Monte Carlo code, BEAMnrc06, was used to evaluate the x‐ray photon scattering kernel, point spread function, and the simulated exposed dose level. Results: Our preliminary results indicated that the various noise properties can be quantified by using the noise simulation and noise power spectrum calculations. The scattering kernel was determined by using the Monte Carlo method according to the actual x‐ray tube geometry and was in agreement with the experimental measurement. Lower bound of the delivered dose level was determined based on the simulated low‐dose images reconstructed form the higher‐dose images. The motion artifact was also quantified based on the Fourier analysis in the spatial frequency domain. Conclusion: We have developed a computer simulation package where the key substances such as the quantum noise were included. The simulated results were used to quantify the micro CT imager and the optimized system performance can be achieved.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here