Monte Carlo simulations of absorbed dose in a mouse phantom from 18‐fluorine compounds
Author(s) -
Taschereau Richard,
Chatziioannou Arion F.
Publication year - 2007
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2558115
Subject(s) - imaging phantom , absorbed dose , monte carlo method , biodistribution , dosimetry , nuclear medicine , voxel , internal dosimetry , effective dose (radiation) , medical imaging , materials science , biomedical engineering , medical physics , physics , chemistry , medicine , mathematics , statistics , radiology , in vitro , biochemistry
The purpose of this study was to calculate internal absorbed dose distribution in mice from preclinical small animal PET imaging procedures with fluorine‐18 labeled compounds ( FDG18 , FLT18 , and fluoride ion). The GATE Monte Carlo software and a realistic, voxel‐based mouse phantom that included a subcutaneous tumor were used to perform simulations. Discretized time‐activity curves obtained from dynamic in vivo studies with each of the compounds were used to set the activity concentration in the simulations. For FDG18 , a realistic range of uptake ratios was considered for the heart and tumor. For each simulated time frame, the biodistribution of the radionuclide in the phantom was considered constant, and a sufficient number of decays were simulated to achieve low statistical uncertainty. Absorbed dose, which was scaled to take into account radioactive decay, integration with time, and changes in biological distribution was reported in mGy per MBq of administered activity for several organs and uptake scenarios. The mean absorbed dose ranged from a few mGy/MBq to hundreds of mGy/MBq. Major organs receive an absorbed dose in a range for which biological effects have been reported. The effects on a given investigation are hard to predict; however, investigators should be aware of potential perturbations especially when the studied organ receives high absorbed dose and when longitudinal imaging protocols are considered.