TU‐D‐224C‐05: Validation of a Linear Accelerator Source Model and Commissioning Process for Routine Clinical Monte Carlo Calculations
Author(s) -
Cui J,
Zakaryan K,
Alaly J,
Vicic M,
Wiesmeyer M,
Deasy J
Publication year - 2006
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2241563
Subject(s) - monte carlo method , linear particle accelerator , medical physics , process (computing) , computer science , statistical physics , computational physics , physics , mathematics , statistics , optics , beam (structure) , operating system
Purpose: Many source models for Monte Carlo treatment planning include parameters which are difficult or ambiguous to determine. We developed and tested a straightforward source model and commissioning process for clinical Monte Carlo calculations. Method and Materials: Our commissioning process of fitting treatment planning system data includes fitting the photon spectrum, electron contamination, penumbra fluence blurring, jaw leakage, and the flattening filter effect. The energy spectrum is fit using a modified Fatigue Life Distribution multiplied by a Fermi. Electron contamination is modeled separately an exponential function, as suggested by Fippel. Penumbral blurring is modeled using a Gaussian filter. Leakage radiation is modeled as a low‐intensity wide‐field monoenergetic source. The flattening filter effect is modeled by multiplying the optimized fluence by a Gaussian reduction. The penumbra and the flattening filter are applied to the fluence map. We tested our methodology on doses produced by a Varian accelerator for 6 MV and 18 MV photons and 5×5, 10×10, and 20×20 cm 2 field sizes. Results: We found that nine published photon spectra of Varian, Eleckta, and Siemens linear accelerators, ranging in energy from 4 MV to 25 MV could be modeled by the Fatigue Life Distribution with a Fermi cutoff. The agreement between the TPS doses and the commissioned MC doses were within 2%. Off‐axis energy spectrum softening was unneeded. Conclusion: We have developed a straightforward, yet flexible source modeling system. The commissioning process affords a high‐degree of automation with an unambiguous determination of the relevant parameters. Commissioning of clinical Monte Carlo treatment planning systems is facilitated by using a source model which is only as complicated as necessary to accurately simulates dose distributions. Conflict of Interest: This research was partially supported by NIH grant R01 CA90445 and a grant from Sun Nuclear, Corp.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here