z-logo
Premium
TU‐D‐330A‐07: A Fast Pseudo‐1D Active Contour for Medical Image Segmentation
Author(s) -
Sensakovic W,
Armato S,
Starkey A
Publication year - 2006
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2241552
Subject(s) - medical imaging , image segmentation , computer vision , active contour model , artificial intelligence , segmentation , image (mathematics) , computer science , pattern recognition (psychology)
Purpose: A snake (active contour) is a deformable curve used in medical image processing to localize region boundaries. The time required for snake convergence to a solution is lengthened by increased data set size and complex external energy field computations. A new gradient vector flow (GVF) snake algorithm was developed to increase the convergence speed of the conventional GVF snake algorithm. Method and Materials: The new algorithm reformulates a 2D closed curve to a pseudo‐1D open curve. This transformation reduces the solution search space and the area for external energy field computation. Further, curve deformations are restricted to one dimension, thus reducing the complexity for both deformation and external field computation. A binary 512×512 test image was created and the algorithms were run using each of three initializations. Additionally, both algorithms were applied to a 512×512 thoracic CT section. Results: The new algorithm, on average, converged to a solution for the binary image in 11.1s compared with 14.6s for the conventional algorithm (24% improvement). The greatest gains were seen in the GVF calculation where the mean reduction in time for GVF calculation alone was 2.9s (32% improvement). The time for contour fitting was also consistently decreased, with a mean reduction for fitting of 0.6s (11% improvement). The new algorithm on average converged to a solution for the CT section in 4.01s compared with 7.15s for the conventional algorithm (44% improvement). Area‐of‐overlap measures for the contours generated by both algorithms exceeded 0.97 for both binary and CT test images. Conclusion: A new active contour algorithm was developed, and a consistent speed improvement over the conventional algorithm was measured. This new algorithm is compatible with other optimization techniques and shows potential for processing large medical image data sets. Conflict of Interest: S.G.A shareholder R2 Technology, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here