z-logo
Premium
SU‐FF‐J‐107: Predicting Dosimetric Errors From Real‐Time Tumor Tracking Using a Treatment Couch During IMRT Delivery
Author(s) -
D'Souza W,
Nazareth D,
Naqvi S,
McAvoy T
Publication year - 2006
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2240883
Subject(s) - trajectory , tracking (education) , controller (irrigation) , control theory (sociology) , residual , displacement (psychology) , mathematics , nuclear medicine , monte carlo method , computer science , physics , medicine , algorithm , statistics , artificial intelligence , control (management) , pedagogy , psychology , astronomy , agronomy , psychotherapist , biology
Purpose: To determine the dosimetric errors resulting from real‐time tumor tracking using a treatment couch‐based feedback control system. Methods: The couch dynamics and controller were modeled as a closed‐loop feedback control system. A real‐time tumor trajectory was input into the control system and the resulting output residual tumor motion trajectory was determined as a function of varying parameters (time constants and dead times) used to describe the system dynamics. The residual motion trajectory served as the input for a Monte Carlo superposition dose calculation algorithm that sampled the position of the tumor according to the displacement distribution from the residual tumor trajectory. We considered tumor trajectory data from a lung tumor case and applied it to a 7‐field IMRT plan in which the prescribed dose was 66 Gy. The motion influenced dose distributions were compared with the “static” and tumor motion without feedback control cases. Results: The fraction of tumor displacements greater than 3 mm for uncontrolled motion was 0.72, 0.32 for the case in which the couch dynamics were described by two equal time constants of 0.135 s and a dead time of 0.27 s and the controller described by a time constant of 0.20 s. For even smaller time constants and dead times, this fraction reduced to < 0.05. The volume of the GTV receiving the prescription dose was 99% for the static case, 68.9% when uncontrolled tumor motion is present and 98.3% when feedback control is employed and the fraction of tumor displacements > 3 mm is 0.32. Conclusion: Our results show that real‐time tumor tracking may be achieved using a treatment couch with < 2% degradation in tumor volumes receiving the prescribed dose. The motion‐influenced dose distributions are more dependent on the distribution of residual tumor displacements than on the maximum instantaneous displacement.

This content is not available in your region!

Continue researching here.