z-logo
Premium
SU‐FF‐I‐81: Gamma Camera Guided Permanent Breast 103Pd Seed Implantation
Author(s) -
Ravi A,
Caldwell C,
Keller B,
Pignol J
Publication year - 2006
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2240761
Subject(s) - imaging phantom , gamma camera , brachytherapy , monte carlo method , nuclear medicine , collimator , medical imaging , physics , materials science , biomedical engineering , optics , medicine , mathematics , radiology , radiation therapy , statistics
Objective: To assess whether a proposed SPECT device could address the requirements of resolving distributions of permanent breast brachytherapy103 Pd seeds following implantation; while maintaining an acceptable imaging time to allow for correction of misplaced seeds. Method: Monte Carlo simulations of a cadmium zinc telluride crystal‐based gamma camera were used to assess whether the detection of 22 keV photons emitted from the103 Pd seeds was feasible. A hexagonal parallel hole collimator, hole length 38 mm, diameter 1.2 mm with 0.2 mm septa was modeled. The design of the gamma camera device was evaluated on two phantom models. The first model consisted of a simple representation of the clinical problem by simulating the breast as 8 cm diameter sphere of breast tissue containing a central, 1cm cubic distribution of 8 seeds. The second simulation presented a more accurate depiction of the clinical problem, where the breast model was based on the pre‐implant CT scan of a typical breast brachytherapy patient and the activity was simulated from the patient's corresponding treatment plan. Results: The spherical phantom yielded promising results after 24 s of imaging time, where the maximum error between the center of mass of the seeds in the reconstructed image and the simulated seed location was 1.02 mm. The results from the clinically accurate simulation revealed that individual seeds could not be identified from the reconstructed images after 2 minutes of imaging. However, the strands of seeds, arranged in each needle were localized to a maximum error of 1.9 mm. Conclusion: The online gamma‐camera approach to imaging the103 Pd seeds is feasible for simple seed distributions. Additional improvements to the collimator design and the gamma camera orbit are required before the gamma camera device will be able to distinguish each seed in an implanted seed distribution.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here