A three‐dimensional reconstruction algorithm for an inverse‐geometry volumetric CT system
Author(s) -
Schmidt Taly Gilat,
Fahrig Rebecca,
Pelc Norbert J.
Publication year - 2005
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.2064827
Subject(s) - algorithm , iterative reconstruction , projection (relational algebra) , reconstruction algorithm , cartesian coordinate system , optical transfer function , sampling (signal processing) , noise (video) , detector , computer science , plane (geometry) , grid , geometry , computer vision , mathematics , optics , physics , image (mathematics)
An inverse‐geometry volumetric computed tomography (IGCT) system has been proposed capable of rapidly acquiring sufficient data to reconstruct a thick volume in one circular scan. The system uses a large‐area scanned source opposite a smaller detector. The source and detector have the same extent in the axial, or slice, direction, thus providing sufficient volumetric sampling and avoiding cone‐beam artifacts. This paper describes a reconstruction algorithm for the IGCT system. The algorithm first rebins the acquired data into two‐dimensional (2D) parallel‐ray projections at multiple tilt and azimuthal angles, followed by a 3D filtered backprojection. The rebinning step is performed by gridding the data onto a Cartesian grid in a 4D projection space. We present a new method for correcting the gridding error caused by the finite and asymmetric sampling in the neighborhood of each output grid point in the projection space. The reconstruction algorithm was implemented and tested on simulated IGCT data. Results show that the gridding correction reduces the gridding errors to below one Hounsfield unit. With this correction, the reconstruction algorithm does not introduce significant artifacts or blurring when compared to images reconstructed from simulated 2D parallel‐ray projections. We also present an investigation of the noise behavior of the method which verifies that the proposed reconstruction algorithm utilizes cross‐plane rays as efficiently as in‐plane rays and can provide noise comparable to an in‐plane parallel‐ray geometry for the same number of photons. Simulations of a resolution test pattern and the modulation transfer function demonstrate that the IGCT system, using the proposed algorithm, is capable of 0.4 mm isotropic resolution. The successful implementation of the reconstruction algorithm is an important step in establishing feasibility of the IGCT system.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here