z-logo
Premium
SU‐FF‐T‐404: Fractionated Radiosurgery by Adaptation of Resources
Author(s) -
Batchelar D,
Bauman G,
Fisher B,
Taylor J,
Wong E
Publication year - 2005
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.1998203
Subject(s) - radiosurgery , imaging phantom , collimator , fiducial marker , optics , nuclear medicine , dosimetry , beam (structure) , physics , materials science , computer science , computer vision , medicine , radiation therapy , radiology
Purpose: Our goal was to integrate broadly accessible, multi‐purpose tools to form a system for non‐invasive MLC‐based fractionated radiosurgery. We investigated the use of a Varian Millennium MLC (mMLC, 5mm‐leaf resolution) in conjunction with an aSi electronic portal imaging device (EPID) and Varian ZMed RadioCamera system for this purpose. Method and Materials: Pinpoint and RK chambers were used to measure data from small fields (mMLC shaped). Profiles for field sizes ranging from 4×4 to 1×1‐cm were measured in water, while output measurements were taken in a MedTec IMRT phantom. These data were used to commission an mMLC radiosurgery (fRS) beam in Theraplan Plus v3.8. Dose distributions created with this beam were compared both to measurement and circular collimator‐based SRS distributions. The RadioCamera system consists of an infrared camera and customized biteblock equipped with infrared markers. This detects motion in real time and allows the beam to be halted when a threshold is reached. The radio‐opaque markers are also used as a fiducial system for EPID. The motion sensitivity threshold and consistency of the biteblock‐mounted fiducials were both examined. Finally, the full system was tested using a film phantom outfitted with a biteblock. Results: Planning system predictions using the fRS beam match measured profiles, depth doses and output factors. Plans created with this beam were shown to approach those created using radiosurgery cones, based on DVH, homogeneity and conformity analyses. The IR camera system is sensitive to 0.2mm motion in all directions. Overall system test indicated that we can treat 1cm lesions with 0.3cm PTV and MLC margins. Conclusion: Our studies indicate that the combination of mMLC, infrared motion tracking, and EPID verification is sufficient to form a practical system for non‐invasive, fractionated radiosurgery, comparable to conventional linac‐based radiosurgery. This system is being used clinically at our institution.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here