SU‐FF‐T‐308: Determination of Output, Percentage Depth Dose (PDD) and Effective Source to Skin Distance (SSDeff) for Irregular Electron Fields
Author(s) -
Somarriba F,
Venencia C,
Besa P
Publication year - 2005
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.1998037
Subject(s) - imaging phantom , ionization chamber , electron , cathode ray , physics , software , dosimetry , monitor unit , optics , computational physics , ionization , computer science , nuclear medicine , nuclear physics , medicine , ion , programming language , quantum mechanics
Purpose: The sector integration method (SIM) has been described in the literature as a simple alternative to calculate the output for irregular electron fields. However, full characterization of the electron beam data (output and PDD) is necessary for the clinical use. The purpose of this work is to develop and commission new software using the SIM to calculate the output, PDD and SSDeff for irregular electron fields, compare the results with pencil beam algorithm calculation and measured data. Method and Materials: A Clinac 2300CD (Varian) with energies of 6, 9, 12, 15, 18 and 22 MeV was used. A set of circular electron cut‐outs, of different radios, were made for applicator sizes of 6×6 cm. and 15×15 cm. Measurements were done with a PTW Markus ionization chamber, an automatic phantom (Scanditronix‐Wellhofer) for PDD and a standard water phantom for output and SSD eff determination. Software was developed using Delphi 6.0. This software divides the irregular field in sectors (4, 8, 16, 32) and average the contribution for each one. A set of 15 cut‐outs (square, rectangular and irregular) were build for verification. For each cut‐out and electron energy the output, PDD and SSD eff were calculated with the new software and compared to chamber measurements. The treatment planning system (TPS) CadPlan (Varian) was used to calculate PDD. Results: The measured and calculated output differences for rectangular and squares fields were less than 1% and for irregular fields less than 3%. The PDD variations between measured and new software calculated were smaller than 2mm. The new software PDD agrees within 2mm with the TPS and ion chamber measurements, except for 6MeV were the differences were less than 3mm. Conclusion: The new software offers a simple and exact tool to calculate output and PDD curves for irregular electron fields with errors clinically acceptable.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here