z-logo
Premium
SU‐FF‐I‐45: Effects of Patient Positions On PET Tumor Volume Assessment in Lung Cancer
Author(s) -
Jang S,
Tran H,
Alavi A
Publication year - 2005
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.1997525
Subject(s) - image registration , coronal plane , nuclear medicine , lung cancer , voxel , medicine , medical imaging , image fusion , positron emission tomography , radiology , artificial intelligence , computer science , image (mathematics) , pathology
Purpose: The purpose of this study is to investigate the effects of different patient positions on the PET and CT image registration, and to delineate more accurate PET metabolic tumor volumes (MTVs) using a deformable image registration in lung cancer. When PET and CT systems are used as stand alone modalities, the patient arm positions are usually different. We used a deformable image registration method to fuse PET and CT images with different patient positions. Method and Materials: PET and CT images were acquired for 10 lung cancer patients. Both arms were placed at sides for PET imaging, but arms were up for CT imaging. The images were registered using an iterative non‐rigid algorithm (REVEAL‐MVS) based on voxel intensities. The displacements after the image registration were measured in the lung boundaries with axial and coronal images. The MTV and its mean standardized uptake value (SUV) in the PET images were measured before and after the non‐rigid image registration. Results: The displacements in the lung boundaries and diaphragm ranged from 1.85 to 3.89 cm for coronal images and from 1.57 to 2.42 cm for axial images. In 5 out of 10 cases the PET‐MTV became greater and the mean SUV became smaller after the non‐rigid image registration. The PET MTVs before and after the deformable image registration resulted in the volume differences of −1.8 cm 3 to +29.3 cm 3 and in the percent difference of −25% to ±41%. Conclusion: The different patient positions (arms‐down for PET; arms‐up for CT) in stand alone PET and CT systems yielded different PET tumor volume, extent and location. The non‐rigid image registration should be used to obtain more accurate PET MTV and its location. The PET MTV using a deformable registration method may be utilized for CT‐based radiation treatment planning in lung cancer.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here