SU‐EE‐A1‐01: Comparison of Monte Carlo and Convolution/Superposition Calculation Methods: Quantification of the Dose Prediction Errors Arising From Tissue Heterogeneities
Author(s) -
Mihaylov I,
Lerma F,
Siebers J
Publication year - 2005
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.1997471
Subject(s) - monte carlo method , nuclear medicine , superposition principle , convolution (computer science) , intensity modulation , mathematics , dosimetry , collimator , imaging phantom , algorithm , head and neck , physics , computer science , medicine , statistics , mathematical analysis , optics , artificial intelligence , phase modulation , artificial neural network , phase noise , surgery
Purpose: To investigate the extent of the dose prediction error (DPE) due to tissue heterogeneities in superposition/convolution (SC) based dose calculations by comparisons with Monte Carlo (MC) calculations for head‐and‐neck IMRT treatment plans. Method and Materials: A retrospective investigation is performed for ten Head‐and‐Neck IMRT patients. Dose calculations are performed with SC and MC algorithms. For both algorithms, the intensity modulation generated by the dynamic multi‐leaf collimator (DMLC) is incorporated into the dose calculation via a transmission matrix generated by determining the ratio of incident and transmitted energy fluence through the DMLC using a MC algorithm. Plans were compared based upon the criteria used during the IMRT optimization: GTV D 98 , CTV D 95 , Nodal volume D 90 , Cord D 02 , and Parotid D 50 . As the same transmission matrix is used for both methods and the SC and MC algorithms subsequent dose differences are attributed to handling of the tissue heterogeneities by the SC algorithm. Results: The GTV D 98 and CTV D 95 local doses agree within ±3.2% for the SC and MC calculations. Differences are within ±1.8% for the D 90 of the nodal target volume. The cord and the brainstem D 02 doses differ by <±3.5% and <±2.5% of the local dose respectively. The Parotid D 50 shows the greatest variations, with local differences up to 5.8%. The observed deviations do not show systematic under‐ or over‐estimate of the dose by SC. Conclusion: When identical transmission matrices are used, the DPE of the SC method, using the MC method as a references, is <±3.2% for the target structures. For the critical structures, DPEs as high as 6% of the local dose were observed, which corresponds to <3% if normalized to the prescription dose. (Supported by NIH‐1R01CA98524)