z-logo
Premium
Particle selection and beam collimation system for laser‐accelerated proton beam therapy
Author(s) -
Luo Wei,
Fourkal Eugene,
Li Jinsheng,
Ma ChangMing
Publication year - 2005
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1118/1.1861772
Subject(s) - collimator , proton therapy , magnet , collimated light , proton , pencil beam scanning , physics , beam (structure) , magnetic field , pencil (optics) , atomic physics , charged particle , particle accelerator , particle therapy , optics , nuclear physics , computational physics , laser , ion , quantum mechanics
In a laser‐accelerated proton therapy system, the initial protons have broad energy and angular distributions, which are not suitable for direct therapeutic applications. A compact particle selection and collimation device is needed to deliver small pencil beams of protons with desired energy spectra. In this work, we characterize a superconducting magnet system that produces a desired magnetic field configuration to spread the protons with different energies and emitting angles for particle selection. Four magnets are set side by side along the beam axis; each is made of NbTi wires which carry a current density of ∼ 10 5A ∕ cm 2 at 4.2 K, and produces a magnetic field of ∼ 4.4 T in the corresponding region. Collimation is applied to both the entrance and the exit of the particle selection system to generate a desired proton pencil beam. In the middle of the magnet system, where the magnetic field is close to zero, a particle selection collimator allows only the protons with desired energies to pass through for therapy. Simulations of proton transport in the presence of the magnetic field show that the selected protons have successfully refocused on the beam axis after passing through the magnetic field with the optimal magnet system. The energy spread for any given characteristic proton energy has been obtained. It is shown that the energy spread is a function of the magnetic field strength and collimator size and reaches the full width at half maximum of 25 MeV for 230 MeV protons. Dose distributions have also been calculated with the GEANT3 Monte Carlo code to study the dosimetric properties of the laser‐accelerated proton beams for radiation therapy applications.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here