z-logo
open-access-imgOpen Access
Effects of image lag on real-time target tracking in radiotherapy
Author(s) -
Rie Tanaka,
Katsuhiro Ichikawa,
Shinichiro Mori,
Suguru Dobashi,
Motoki Kumagaya,
Hiroki Kawashima,
Shinichi Morita,
Shigeru Sanada
Publication year - 2010
Publication title -
proceedings of spie, the international society for optical engineering/proceedings of spie
Language(s) - English
Resource type - Conference proceedings
SCImago Journal Rank - 0.192
H-Index - 176
eISSN - 1996-756X
pISSN - 0277-786X
DOI - 10.1117/12.844202
Subject(s) - tracking (education) , computer vision , artificial intelligence , detector , computer science , time delay and integration , image sensor , lag , flat panel detector , optics , physics , computer network , psychology , pedagogy
There is a concern that image lag may reduce accuracy of real-time target tracking in radiotherapy. This study was performed to investigate influence of image lag on the accuracy of target tracking in radiotherapy. Fluoroscopic image: were obtained using a direct type of dynamic flat-panel detector (FPD) system under conditions of target tracking during radiotherapy. The images continued to be read out after X-irradiations and cutoff, and image lag properties in the system were then determined. Subsequently, a tungsten materials plate with a precision edge was mounted on to a motor control device, which provided a constant velocity. The plate was moved into the center of the detector at movement rate of 1 and 20 mm/s, covering lung tumor movement of normal breathing, and MTF and profile curves were measured on the edges covering and uncovering the detector. A lung tumor with blurred edge due to image lag was simulated using the results and then superimposed on breathing chest radiographs of a patient. The moving target with and without image lag was traced using a template-matching technique. In the results, the target could be traced within a margin for error ii external radiotherapy. The results indicated that there was no effect of image lag on target tracking in usual breathing speed in a radiotherapy situation. Further studies are required to investigate influence by the other factors, such a: exposure dose, target size and shape, imaging rate, and thickness of a patient's body. © 2010 SPIE

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom