Detection of microcalcification clusters by 2D-mammography and narrow and wide angle digital breast tomosynthesis
Author(s) -
Andria Hadjipanteli,
Premkumar Elangovan,
Pádraig T. Looney,
Alistair Mackenzie,
Kevin Wells,
David R. Dance,
Kenneth C. Young
Publication year - 2016
Publication title -
proceedings of spie, the international society for optical engineering/proceedings of spie
Language(s) - English
Resource type - Conference proceedings
SCImago Journal Rank - 0.192
H-Index - 176
eISSN - 1996-756X
pISSN - 0277-786X
DOI - 10.1117/12.2217663
Subject(s) - digital breast tomosynthesis , microcalcification , tomosynthesis , mammography , digital mammography , computer science , artificial intelligence , computer vision , medicine , breast cancer , cancer
The aim of this study was to compare the detection of microcalcification clusters by human observers in breast images using 2D-mammography and narrow (15°/15 projections) and wide (50°/25 projections) angle digital breast tomosynthesis (DBT). Simulated microcalcification clusters with a range of microcalcification diameters (125 μm-275 μm) were inserted into 6 cm thick simulated compressed breasts. Breast images were produced with and without inserted microcalcification clusters using a set of image modelling tools, which were developed to represent clinical imaging by mammography and tomosynthesis. Commercially available software was used for image processing and image reconstruction. The images were then used in a series of 4-alternative forced choice (4AFC) human observer experiments conducted for signal detection with the microcalcification clusters as targets. The minimum detectable calcification diameter was found for each imaging modality: (i) 2D-mammography: 164±5 μm (ii) narrow angle DBT: 210±5 μm, (iii) wide angle DBT: 255±4 μm. A statistically significant difference was found between the minimum detectable calcification diameters that can be detected by the three imaging modalities. Furthermore, it was found that there was not a statistically significant difference between the results of the five observers that participated in this study. In conclusion, this study presents a method that quantifies the threshold diameter required for microcalcification detection, using high resolution, realistic images with observers, for the comparison of DBT geometries with 2D-mammography. 2Dmammography can visualise smaller detail diameter than both DBT imaging modalities and narrow-angle DBT can visualise a smaller detail diameter than wide-angle DBT

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom