z-logo
Premium
Lung volume does not alter the distribution of pulmonary perfusion in dependent lung in supine humans
Author(s) -
Hopkins Susan R.,
Arai Tatsuya J.,
Henderson A. Cortney,
Levin David L.,
Buxton Richard B.,
Prisk G. Kim
Publication year - 2010
Publication title -
the journal of physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.802
H-Index - 240
eISSN - 1469-7793
pISSN - 0022-3751
DOI - 10.1113/jphysiol.2010.196063
Subject(s) - lung , supine position , perfusion , lung volumes , functional residual capacity , nuclear medicine , medicine , chemistry
There is a gravitational influence on pulmonary perfusion, including in the most dependent lung, where perfusion is reduced, termed Zone 4. Studies using xenon‐133 show Zone 4 behaviour, present in the dependent 4 cm at total lung capacity (TLC), affects the dependent 11 cm at functional residual capacity (FRC) and almost all the lung at residual volume (RV). These differences were ascribed to increased resistance in extra‐alveolar vessels at low lung volumes although other mechanisms have been proposed. To further evaluate the behaviour of perfusion in dependent lung using a technique that directly measures pulmonary perfusion and corrects for tissue distribution by measuring regional proton density, seven healthy subjects (age = 38 ± 6 years, FEV 1 = 104 ± 7% predicted) underwent magnetic resonance imaging in supine posture. Data were acquired in the right lung during breath‐holds at RV, FRC and TLC. Arterial spin labelling quantified regional pulmonary perfusion, which was normalized for regional proton density measured using a fast low‐angle shot technique. The height of the onset of Zone 4 behaviour was not different between lung volumes ( P = 0.23). There were no significant differences in perfusion (expressed as ml min −1 g −1 ) between lung volumes in the gravitationally intermediate (RV = 8.9 ± 3.1, FRC = 8.1 ± 2.9, TLC = 7.4 ± 3.6; P = 0.26) and dependent lung (RV = 6.6 ± 2.4, FRC = 6.1 ± 2.1, TLC = 6.4 ± 2.6; P = 0.51). However, at TLC perfusion was significantly lower in non‐dependent lung than at FRC or RV (3.6 ± 3.3, 7.7 ± 1.5, 7.9 ± 2.0, respectively; P < 0.001). These data suggest that the mechanism of the reduction in perfusion in dependent lung is unlikely to be a result of lung volume related increases in resistance in extra‐alveolar vessels. In supine posture, the gravitational influence on perfusion is remarkably similar over most of the lung, irrespective of lung volume.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here