z-logo
Premium
The regularity of muscle spindle discharge in man.
Author(s) -
Burke D,
Skuse N F,
Stuart D G
Publication year - 1979
Publication title -
the journal of physiology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.802
H-Index - 240
eISSN - 1469-7793
pISSN - 0022-3751
DOI - 10.1113/jphysiol.1979.sp012812
Subject(s) - ankle , muscle spindle , afferent , plantar flexion , anatomy , contraction (grammar) , chemistry , medicine
1. The variability of discharge of thirty‐nine muscle spindle afferents from the pretibial muscles of normal human subjects was determined for spike train sequences recorded with the ankle joint fixed in 25 degrees plantar flexion, during further stretch and during graded voluntary contractions of the receptor‐bearing muscle. 2. In non‐contracting muscles with the ankle joint in 25 degrees plantar flexion, a sustained discharge was maintained by twenty‐four of the thirty‐nine endings. The mean discharge frequency for the active endings was 11.1 Hz (range 4.8‐‐22.1 Hz), the mean coefficient of variation 0.073 (range 0.021‐‐0.183). With further stretch, the discharge of endings maintaining frequencies below 10‐‐12 Hz became more regular. For endings maintaining higher frequencies, changes in the coefficient of variation were small and occurred in either direction. All secondary endings maintained a highly regular discharge, but, at these frequencies, there was no statistically significant difference in the variability of primary and secondary endings. 3. It is considered that these findings are comparable to those of Matthews & Stein (1969) for de‐efferented feline spindle endings, and support the view that there is no functionally effective background fusimotor drive to non‐contracting muscles of normal human subjects. 4. A voluntary contraction sufficient to accelerate a spindle ending invariably decreased the regularity of its afferent discharge. During voluntary contractions, coefficients of variation up to 0.345 were recorded. However, coefficients as low as 0.1 were not uncommon, and thus the absence of fusimotor drive cannot necessarily be inferred from a regular afferent discharge pattern. 5. With contractions of different strength, the increase in the coefficient of variation did not parallel the increase in discharge frequency. It is concluded that not all fusimotor influences acting on a spindle ending are translated into variability, and that measurements of the variability of discharge do not accurately reflect the level of fusimotor drive. 6. The discharge frequency of some spindle endings decreased slightly in some contractions and this was accompanied by an increase in the variability of discharge. It is suggested that contracting extrafusal muscle fibres can modulate the discharge pattern of spindle endings and contribute to the variability of discharge during a voluntary contraction. 7. In contracting muscles the irregular fusimotor‐driven spindle discharge contained a ‘hidden’ periodicity, but this was not as extensive as has been reported for the cat. No such periodicity could be demonstrated for spindle endings in non‐contracting human muscles.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here