z-logo
open-access-imgOpen Access
Effect of Liquid Inhibitor De-dioTM on Dioxin-Furan Emission From Medical Waste Incineration Plant
Author(s) -
Mariyah Rashid,
Mohammad Firuz Ramli,
Mohammed Ammar,
K. Noorhafizah
Publication year - 2014
Publication title -
jurnal teknologi/jurnal teknologi
Language(s) - English
Resource type - Journals
eISSN - 2180-3722
pISSN - 0127-9696
DOI - 10.11113/jt.v69.2223
Subject(s) - incineration , furan , flue gas , medical waste , combustion , waste management , environmental science , chemistry , environmental chemistry , organic chemistry , engineering
The aim of the study was to investigate the effects of liquid inhibitor (known as De-dioTM) on the emission of dioxin-furan from medical waste incineration plants.  Various concentrations of De-dioTM solutions were tested on the medical waste incinerator combustion chamber with an injection flow rate of 1.5 L/min. The sampling protocol of US EPA Method 23 was adopted to collect the sample using a modified US EPA Method 5 sampling train. The flue gas emission was collected before and during the injection of the chemical. The result showed that the De-dioTM was able to reduce or minimize the formation of dioxin-furan to meet its regulatory limits. The study illustrates that the higher the concentration of De-dioTM solution, the lower the dioxin-furan emission was observed in the flue gas.  

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here