
Analysis on the Effect of Capacitor Banks Operation towards Total Harmonic Distortions (THD) in Distribution Network Test System
Author(s) -
Dalila,
Zaris I.M.Y.,
A A Nasarudin,
H Faridah
Publication year - 2018
Publication title -
journal of energy and safety technology
Language(s) - English
Resource type - Journals
ISSN - 2637-1030
DOI - 10.11113/jest.v1n2.21
Subject(s) - total harmonic distortion , thd analyzer , capacitor , software , voltage , computer science , distortion (music) , sizing , harmonic , electrical engineering , node (physics) , electronic engineering , engineering , physics , nonlinear distortion , acoustics , art , amplifier , structural engineering , cmos , visual arts , programming language
This paper purposely to examine and analyse the impact of the distribution capacitors banks operation to the transition of total harmonic distortion (THD) level in distribution network system. The main advantage of this work is the simplicity algorithm of the method and the system being analysed using free access open software which is known as electric power distribution system simulator (OpenDSS). In this paper, the harmonic current spectrum which is collected from the commercial site was injected to a node point on IEEE13 bus in order to provide the initial measurement of THD for the network. The proper sizing of the capacitors banks has been set and being deactivated and activated throughout the network to see the transistion in the THD level in the system. The results were achieved by simulation of the data on the configured IEEE13 bus. The simulation work was done by using the combination of C++ source codes, OpenDSS and Microsoft Excel software. From the output results, the THD current has increased up to two times from the initial value in certain phases and for the THD voltage, the THD has increased up to three times from its initial value in all phases.