z-logo
Premium
Biomechanical properties of a novel locking compression plate to stabilize oblique tibial osteotomies in buffaloes
Author(s) -
Ahmad Raja A.,
Aithal Hari Prasad,
Kinjavdekar Prakash,
Gope Prakash Chandra,
Madhu Doddadasarahalli N.
Publication year - 2021
Publication title -
veterinary surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.652
H-Index - 79
eISSN - 1532-950X
pISSN - 0161-3499
DOI - 10.1111/vsu.13554
Subject(s) - medicine , ultimate load , compression (physics) , bending , bending moment , orthodontics , stiffness , surgery , composite material , structural engineering , materials science , finite element method , engineering
Objective Quantitation of mechanical properties of a novel locking compression plate (LCP) for bovine tibia. Study design Prospective in vitro study. Sample population Adult Murrah buffalo (250‐350 kg) tibiae. Methods Forty tibiae were randomly assigned to five treatment groups (n = 8/group): intact bone and bone constructs with a standard nonlocking plate, single LCP, double LCP, and novel LCP. During implant application, a mid‐diaphyseal, oblique osteotomy was performed in all constructs, which were subsequently tested in axial compression (n = 4 each) or three‐point craniocaudal bending (n = 4 each). Novel LCP alone (n = 4) was tested only in bending. Stiffness, yield load, ultimate failure load, and bending moment were determined from the load deformation curves and compared among different treatment groups ( P  < .05). Results Under compression, yield load of the novel LCP (24.07 ± 3.45 kN) was greater than that of the nonlocking plate (11.10 ± 2.46 kN) and the single LCP (18.01 ± 2.07 kN) but less than that of the double LCP (30.61 ± 1.95 kN), and ultimate failure load of the novel LCP (25.85 ± 4.32 kN) was greater than that of the nonlocking plate (13.18 ± 2.91 kN) but similar to that of the single LCP (21.17 ± 2.33 kN) and the double LCP (32.40 ± 1.46 kN). Bending moment, yield load, and ultimate failure load of the novel LCP were 565.37 ± 79.30 Nm, 7.90 ± 1.14 kN, 9.83 ± 1.38 kN, respectively, which were greater than those of the nonlocking plate and the single LCP but comparable to those of the double LCP. Conclusion The novel LCP developed for bovine tibia was mechanically superior to the standard nonlocking plate or the single LCP and comparable to the double LCP. Clinical significance The novel LCP may provide rigid fixation of tibial diaphyseal fractures in buffaloes and cattle weighing 250 to 350 kg.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here