z-logo
Premium
Survey of Intraoperative Bacterial Contamination in Dogs Undergoing Elective Orthopedic Surgery
Author(s) -
Andrade Natalia,
Schmiedt Chad W.,
Cornell Karen,
Radlinsky MaryAnn G.,
Heidingsfelder Lauren,
Clarke Kevin,
Hurley David J.,
Hinson Whitney D.
Publication year - 2016
Publication title -
veterinary surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.652
H-Index - 79
eISSN - 1532-950X
pISSN - 0161-3499
DOI - 10.1111/vsu.12438
Subject(s) - medicine , contamination , orthopedic surgery , perioperative , microbiological culture , surgery , surgical site infection , surgical team , bacteria , ecology , genetics , biology
Objective To investigate the frequency, source, and risk factors of intraoperative (IO) surgeon and patient bacterial contamination during clean orthopedic surgeries, and to investigate the relationship between IO contamination and surgical site infection (SSI) in dogs. Study Design Prospective clinical study. Sample Population Client‐owned dogs undergoing stifle surgery (n = 100). Methods IO cultures were taken in each case from surgical foot wrap, peri‐incisional skin, surgical gloves, and the surgical team's hands. The environment (operating room [OR] lights, computers, scrub sink faucet, anesthesia gurney, and radiology table) was sampled every 5 months. Bacteria were identified and the contamination of each case was categorized. All gloves from the surgical team were collected and tested for perforations using a water infusion test. Cases were followed for at least 8 weeks to determine the presence or absence of SSI. Perioperative variables were evaluated for association with IO contamination and SSI. Results Bacterial isolates were yielded from 81% of procedures from 1 or more sources; 58% had positive hand cultures, 46% had positive glove cultures, 23% had positive patient skin cultures, and 12% had positive foot wrap cultures. Staphylococcus spp. was the most commonly recovered bacteria. There was no apparent association between IO contamination and SSI. The highest level of environmental contamination was associated with the scrub sink faucet, followed by the radiology table, anesthesia gurney, and OR computers. The IO glove perforation rate was 18%. Conclusion Clean orthopedic procedures commonly had clinically insignificant bacterial contamination. In our study, bacteria responsible for SSI did not appear to colonize the patient in the OR.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here