Premium
Modeling complete removal of risk assessment questions in the USA predicts the risk of HIV exposure in blood recipients could increase despite the use of nucleic acid testing
Author(s) -
Yang H.,
Anderson S. A.,
Forshee R.,
Williams A.,
Epstein J. S.,
Marks P. W.
Publication year - 2016
Publication title -
vox sanguinis
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.68
H-Index - 83
eISSN - 1423-0410
pISSN - 0042-9007
DOI - 10.1111/vox.12375
Subject(s) - nat , residual risk , risk assessment , human immunodeficiency virus (hiv) , blood transfusion , medicine , nucleic acid , psychological intervention , whole blood , blood donor , immunology , environmental health , virology , intensive care medicine , biology , computer science , computer security , genetics , computer network , psychiatry
Background and Objectives The safety of the blood supply in a number of countries is achieved by interventions that include behaviour‐based time‐limited or indefinite deferrals and screening of donated units for transfusion‐transmitted infections. The relatively high sensitivity of nucleic acid testing ( NAT ) used in blood donor screening has raised the question of whether such time‐based deferrals can be eliminated in favour of individual risk assessment. Materials and Methods Data on the annual number of incident human immunodeficiency virus ( HIV ) infections associated with various behaviours and on the performance characteristics of NAT applied to donor screening were used to model the number of potentially infected units that might escape detection in the worst‐case scenario in which individual risk assessment was implemented, but was not effective as a screening tool, and donors did not otherwise self‐select for lower risk. Results In the absence of effective individual risk‐based screening or donor self‐selection, the model predicts that in the United States, an additional 39 (95% CI 35–43) HIV ‐infected units would escape detection by nucleic acid testing, potentially capable of exposing approximately 68 (95% CI 61–75) individuals to the risk of HIV infection through the administration of prepared blood components. Conclusion Despite some inherent uncertainty, the worst‐case scenario of completely ineffective individual risk assessment, absence of donor self‐selection and increased reliance on NAT for blood screening is estimated to be associated with an approximately fourfold increase in the risk of HIV exposure through transfusion in the United States.